Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy
- PMID: 16996866
- DOI: 10.1016/j.amjcard.2006.04.027
Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy
Abstract
Coronary allograft vasculopathy (CAV) is the most important limitation to long-term survival in adult heart transplant recipients and is difficult to detect without intravascular ultrasound (IVUS). We systematically evaluated the image quality of 64-slice multidetector computed tomographic (MDCT) coronary angiography in heart transplant recipients and tested the hypothesis that this modality is comparable to invasive coronary angiography with IVUS for the detection of CAV. Heart transplant recipients (n = 20) underwent invasive coronary angiography with IVUS and MDCT coronary angiography with a 64-slice scanner. Images were systematically analyzed for image quality and the presence of CAV. In addition, multidetector computed tomography and quantitative coronary angiography were used to measure lumen diameters at prespecified locations. Image quality analysis showed that, despite high mean heart rates (77 +/- 7 beats/min) and body mass index (29.5 +/- 5.3 kg/m(2)), 83% of coronary segments were graded as of excellent or good image quality. On average, 95 +/- 9% of the overall visualized length of the coronary arteries was imaged without motion artifacts, and the mean contrast-to-noise ratio was 11.3 +/- 4.6. Compared with IVUS, multidetector computed tomography had a sensitivity of 70%, specificity of 92%, positive predictive value of 89%, and negative predictive value of 77% for the detection of CAV. MDCT vessel diameter measurements correlated well with those obtained from quantitative coronary angiography (R(2) = 0.89). In conclusion, 64-slice multidetector computed tomography provides good to excellent image quality in heart transplant recipients and has moderate to excellent test characteristics for the detection of CAV. Further, MDCT measurements of lumen diameters correlated well with quantitative coronary angiography.
Similar articles
-
Comparison of coronary minimal lumen area quantification by sixty-four-slice computed tomography versus intravascular ultrasound for intermediate stenosis.Am J Cardiol. 2006 Oct 1;98(7):871-6. doi: 10.1016/j.amjcard.2006.04.026. Epub 2006 Aug 4. Am J Cardiol. 2006. PMID: 16996865
-
Comparison of dual source computed tomography versus intravascular ultrasound for evaluation of coronary arteries at least one year after cardiac transplantation.Am J Cardiol. 2009 Nov 15;104(10):1351-6. doi: 10.1016/j.amjcard.2009.06.060. Am J Cardiol. 2009. PMID: 19892049
-
Multidetector-row computed tomography vs. angiography and intravascular ultrasound for the evaluation of the diameter of proximal coronary arteries.Int J Cardiol. 2006 Jun 7;110(1):40-5. doi: 10.1016/j.ijcard.2005.07.011. Epub 2005 Sep 19. Int J Cardiol. 2006. PMID: 16169611
-
Coronary CT angiography.J Nucl Med. 2006 May;47(5):797-806. J Nucl Med. 2006. PMID: 16644750 Review.
-
European Association of Cardiovascular Imaging/Cardiovascular Imaging Department of the Brazilian Society of Cardiology recommendations for the use of cardiac imaging to assess and follow patients after heart transplantation.Eur Heart J Cardiovasc Imaging. 2015 Sep;16(9):919-48. doi: 10.1093/ehjci/jev139. Epub 2015 Jul 2. Eur Heart J Cardiovasc Imaging. 2015. PMID: 26139361 Review.
Cited by
-
Good news on coronary computed tomographic angiography: answers that have questions!Eur Heart J. 2008 Sep;29(17):2070-2. doi: 10.1093/eurheartj/ehn338. Epub 2008 Jul 18. Eur Heart J. 2008. PMID: 18641045 Free PMC article. No abstract available.
-
History of cardiac computed tomography: single to 320-detector row multislice computed tomography.Int J Cardiovasc Imaging. 2009 Apr;25 Suppl 1:31-42. doi: 10.1007/s10554-008-9408-z. Epub 2009 Jan 15. Int J Cardiovasc Imaging. 2009. PMID: 19145476 Review.
-
Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography.Int J Cardiovasc Imaging. 2009 Jan;25(1):91-100. doi: 10.1007/s10554-008-9343-z. Epub 2008 Jul 19. Int J Cardiovasc Imaging. 2009. PMID: 18642098
-
Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience.Eur Radiol. 2008 Sep;18(9):1784-90. doi: 10.1007/s00330-008-0949-2. Epub 2008 May 20. Eur Radiol. 2008. PMID: 18491100 Clinical Trial.
-
Cardiac allograft vasculopathy : complications and imaging studies.Herz. 2011 Oct;36(7):630-6. doi: 10.1007/s00059-010-3373-8. Herz. 2011. PMID: 20981397
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical