Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Feb;80(950):126-31.
doi: 10.1259/bjr/32367104. Epub 2006 Sep 27.

Design and implementation of an electronic data recording and processing system for physics quality control checks in external beam radiotherapy

Affiliations

Design and implementation of an electronic data recording and processing system for physics quality control checks in external beam radiotherapy

I Patel et al. Br J Radiol. 2007 Feb.

Abstract

Quality control (QC) of external beam radiotherapy equipment ensures that commissioning performance is maintained. Paper based data recording is still used for QC, but this is resource intensive in terms of data calculation and processing. Electronic systems of data recording have many advantages; for example, they facilitate the analysis of data on a regular basis, allowing the user to examine the "health" of each machine; they help review and audit local frequencies of each check and can possibly predict component failure. They also allow for secure calculation of results and automatic charting for routine trend analysis. Initially, data recording at our centre was paper-based for daily, weekly and monthly checks. This paper system has been successfully replaced with an electronic system for QC data recording and processing for linear accelerators and superficial units. The system makes use of personal digital assistants and networked laptops for online recording of data, and networked desktop PCs for offline work. The systems of data recording have been designed using the power of macros within Microsoft Excel, which automatically calculate each QC parameter and charts the data recorded for long-term analysis of trends. As of the beginning of 2006, these systems have been fully implemented. The benefits of implementing such a system are numerous, for example, central storage, backup and archiving of data, for greater security and reducing operator errors in calculations. Other benefits are discussed within the paper. In the future, we hope to develop similar systems of data recording for QC checks on other radiotherapy equipment.

PubMed Disclaimer