Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Mar;17(3):675-83.
doi: 10.1007/s00330-006-0405-0. Epub 2006 Sep 29.

Multidetector CT (64 Slices) of the liver: examination techniques

Affiliations

Multidetector CT (64 Slices) of the liver: examination techniques

Andrea Laghi. Eur Radiol. 2007 Mar.

Abstract

Sixty-four-row MDCT, although developed primarily for cardiac imaging, has the potential to have a great impact on liver imaging as well. Liver-imaging protocols with sub-millimeter collimation improve longitudinal spatial resolution, making the acquired dataset a real isotropic volume perfectly designed for optimal three-dimensional rendering and accurate organ and lesion volumetry. The 64-row detector array offers a wide volumetric coverage (up to 40 mm), suitable not only for shortening scanning time and improving spatial resolution, but also for including a large volume per single rotation, particularly useful for accurate CT perfusion studies. In order to take full benefit from the enormous performance offered by new 64-row MDCT scanners, imaging protocols need to be redesigned. Due to the extremely short scanning window, contrast agent injection should be performed at high flow rate and followed by saline bolus chaser; the use of highly concentrated contrast media might be useful. Timing should be accurately calculated either by a test bolus or, better, by using an automatic bolus-detection technique. Radiation exposure is kept under control, using automatic device-modulating dose delivery according to the patient's anatomy. Finally, the evaluation of acquired volumetric datasets needs the extensive use of a dedicated workstation, with software with sophisticated rendering capabilities.

PubMed Disclaimer

References

    1. Eur Radiol. 2003 Dec;13 Suppl 5:M127-8 - PubMed
    1. Radiology. 2003 Nov;229(2):401-7 - PubMed
    1. Surgery. 2004 Apr;135(4):404-10 - PubMed
    1. Radiology. 2001 Mar;218(3):763-7 - PubMed
    1. J Radiol. 2003 Apr;84(4 Pt 2):473-9; discussion 480-3 - PubMed