Comparative Study
. 2006 Oct;142(4):699-701.
doi: 10.1016/j.ajo.2006.04.065.

Real depth vs randot stereotests

Affiliations
Comparative Study

Real depth vs randot stereotests

David A Leske et al. Am J Ophthalmol. 2006 Oct.

Abstract

Purpose: To compare the performance of real depth and Randot stereotests in strabismic and nonstrabismic patients.

Design: Observational case series.

Methods: Stereoacuity was tested in 182 patients with a variety of strabismic conditions, using the Frisby-Davis 2 (FD2) distance stereotest, the near Frisby (nF) (both real depth tests), the Preschool Randot (nR), and Distance Randot (dR) tests (both based on Polaroid vectographs).

Results: Patients appreciated finer disparities with the nF test than the nR test at near and with the FD2 test than the dR test at distance.

Conclusions: The type of stereotest influences measurable thresholds, and the results from different tests are not interchangeable. The choice of test should depend on the question being asked; nF and FD2 would be appropriate for determining presence or absence of stereopsis and best measurable stereopsis. The more rigorous Randot tests would be appropriate for determining subtle changes.

PubMed Disclaimer

References

    1. Frisby JP, Davis H, McMorrow K. An improved training procedure as a precursor to testing young children with the Frisby Stereotest. Eye. 1996;10:286–290. - PubMed
    1. Adams WE, Hrisos S, Richardson S, Davis H, Frisby JP, Clarke MP. Frisby Davis distance stereoacuity values in visually normal children. Br J Ophthalmol. 2005;89:1438–1441. - PMC - PubMed
    1. Holmes JM, Fawcett SL. Testing distance stereoacuity with the Frisby-Davis 2 (FD2) test. Am J Ophthalmol. 2005;139:193–195. - PubMed
    1. Birch E, Williams C, Hunter J, Lapa MC, ALSPAC “Children in Focus” Study Team Random dot stereoacuity of preschool children. J Pediatr Ophthalmol Strabismus. 1997;34:217–222. - PubMed
    1. Fu VLN, Birch EE, Holmes JM. Assessment of New Distance Randot Test in Normal and Strabismic Patients. J AAPOS. 2006;10:419–423. - PubMed

Publication types

LinkOut - more resources