Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla
- PMID: 17021711
- DOI: 10.1007/s00330-006-0368-1
Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla
Abstract
This study investigates the feasibility of imaging the coronary lumen and vessel-wall, using MRI with a radial k-space trajectory at 3 T. Such radial trajectories offer the advantage of greater vessel sharpness than traditional Cartesian trajectories. This field strength offers an increased signal-to-noise ratio (SNR) compared with 1.5 T, which compensates for the slight SNR reduction due to the radial sequence. Images of the coronary lumen were acquired for seven healthy volunteers. In ten volunteers the vessel wall was scanned, with blood suppression using oblique-slab adiabatic re-inversion. Scans were performed during free breathing, using prospective respiratory navigator-gating. Coronary lumen scans had SNR of 16.0+/-1.9 and contrast-to-noise ratio (CNR) of 10.3+/-2.1, showing acceptable image quality. Vessel wall images showed good image quality, with mean SNR of 16.6+/-2.0/5.8+/-2.8/10.1+/-2.2 for vessel wall/lumen/epicardial fat. The wall-blood CNR was 10.7+/-2.7, and wall-fat CNR was 6.5+/-2.5. It is concluded that radial gradient-echo imaging at 3 T is a promising method for coronary vessel-wall imaging, and is also feasible for imaging the coronary lumen.
Similar articles
-
MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging.AJR Am J Roentgenol. 2006 Jun;186(6 Suppl 2):S401-6. doi: 10.2214/AJR.04.1864. AJR Am J Roentgenol. 2006. PMID: 16714616
-
Feasibility of coronary artery wall thickening assessment in asymptomatic coronary artery disease using phase-sensitive dual-inversion recovery MRI at 3T.Magn Reson Imaging. 2013 Sep;31(7):1051-8. doi: 10.1016/j.mri.2013.03.011. Epub 2013 May 1. Magn Reson Imaging. 2013. PMID: 23642801 Free PMC article.
-
MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling.J Magn Reson Imaging. 2006 May;23(5):757-62. doi: 10.1002/jmri.20569. J Magn Reson Imaging. 2006. PMID: 16565947 Clinical Trial.
-
Flow targeted 3D steady-state free-precession coronary MR angiography: comparison of three different imaging approaches.Invest Radiol. 2009 Dec;44(12):757-62. doi: 10.1097/RLI.0b013e3181bfe36c. Invest Radiol. 2009. PMID: 19858729
-
Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.Eur Radiol. 2006 Jan;16(1):1-14. doi: 10.1007/s00330-005-2886-7. Epub 2005 Aug 25. Eur Radiol. 2006. PMID: 16132919 Review.
Cited by
-
Cardiovascular magnetic resonance at 3.0 T: current state of the art.J Cardiovasc Magn Reson. 2010 Oct 7;12(1):55. doi: 10.1186/1532-429X-12-55. J Cardiovasc Magn Reson. 2010. PMID: 20929538 Free PMC article. Review.
-
Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.Int J Cardiovasc Imaging. 2012 Dec;28(8):2027-47. doi: 10.1007/s10554-012-0038-0. Epub 2012 Mar 25. Int J Cardiovasc Imaging. 2012. PMID: 22447266 Review.
-
Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla.Curr Cardiol Rev. 2009 Aug;5(3):237-42. doi: 10.2174/157340309788970351. Curr Cardiol Rev. 2009. PMID: 20676283 Free PMC article.
-
Right coronary wall CMR in the older asymptomatic advance cohort: positive remodeling and associations with type 2 diabetes and coronary calcium.J Cardiovasc Magn Reson. 2010 Dec 30;12(1):75. doi: 10.1186/1532-429X-12-75. J Cardiovasc Magn Reson. 2010. PMID: 21192815 Free PMC article.
-
Magnetic resonance coronary angiography: where are we today?Curr Cardiol Rep. 2013 Feb;15(2):328. doi: 10.1007/s11886-012-0328-0. Curr Cardiol Rep. 2013. PMID: 23307168 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical