Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Jun;18(6):619-26.
doi: 10.1007/s00192-006-0202-y. Epub 2006 Oct 10.

Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model

Affiliations
Comparative Study

Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model

Maja L Konstantinovic et al. Int Urogynecol J Pelvic Floor Dysfunct. 2007 Jun.

Abstract

We compared inflammatory response, fibrosis and biomechanical properties of different polypropylene materials from one manufacturer (Tyco Healthcare) in a rat model for primary fascial repair. Full-thickness abdominal wall defects were primarily repaired using 'overlay' technique. Multifilament implants were Surgipro SPM and SPMW, the latter a wider-weave type of the former. Monofilament SPMM implants and polypropylene suture repair (Surgipro II) served as controls. Explants were evaluated macroscopically and changes in thickness, shrinkage and tensile strength were measured. Inflammatory and connective tissue response was assessed on haematoxylin-eosin and Movat stains. Immunohistochemistry was done to localise rat macrophages/monocytes. Multifilament materials induced a shorter acute inflammatory response and more pronounced chronic inflammatory reaction compared to monofilament implants. Macrophages could be found deep in interstices 7.5 by 12.5 microm. No difference in collagen deposition and neovascularisation was observed. At 90 days time point, explants reconstructed with tighter woven multifilament SPM were weaker than sutured or SPMM controls. Overall shrinkage of 10% was comparable for all groups.

PubMed Disclaimer

Similar articles

Cited by

References

    1. BJOG. 2005 Nov;112(11):1554-60 - PubMed
    1. Am J Surg. 1989 Feb;157(2):188-93 - PubMed
    1. Immunology. 1994 Sep;83(1):140-7 - PubMed
    1. Am J Obstet Gynecol. 2005 May;192(5):1395-8 - PubMed
    1. Eur J Surg. 1996 Oct;162(10):823-5 - PubMed

Publication types