Sustainability in the cardiac cath lab
- PMID: 17033729
- DOI: 10.1007/s10554-006-9148-x
Sustainability in the cardiac cath lab
Abstract
Use of radiation for medical examinations and test is the largest man-made source of radiation exposure. Interventional procedures are only 2% of all radiological procedures, but contribute to about 20% of the total collective dose per head per year. On average, a left ventriculography and coronary angiography corresponds to a radiation exposure for the patient of about 300, a coronary stent to 1,000, a peripheral artery intervention to 1,500 to 2,500, and a cardiac radiofrequency ablation to 900-1,500 chest x-rays. Invasive cardiology procedures increased tenfold in the last ten years and growth in the field has been accompanied by concern for the safety of the staff. Interventional cardiologists have an exposure per-head per year two- to three times higher than that of radiologists, with an annual exposure equivalent to around 250 chest x-rays per head. A reduction of occupational doses by a factor of ten can be achieved simply by and intensive training program. The awareness of radiation effects may be suboptimal in the medical community. It is recommended by professional guidelines and reinforced by the European law that the responsibility of all physicians is to minimize the radiation injury hazard to their patients, to their professional staff and to themselves.
Comment on
-
Impact of intracardiac echocardiography on radiation exposure during adult congenital heart disease catheter-based interventions.Int J Cardiovasc Imaging. 2007 Apr;23(2):139-42. doi: 10.1007/s10554-006-9125-4. Epub 2006 Jul 5. Int J Cardiovasc Imaging. 2007. PMID: 16821119 Clinical Trial.
Similar articles
-
Recommendations for occupational radiation protection in interventional cardiology.Catheter Cardiovasc Interv. 2013 Jul 1;82(1):29-42. doi: 10.1002/ccd.24694. Epub 2013 Mar 8. Catheter Cardiovasc Interv. 2013. PMID: 23475846 Review.
-
An In-depth Analysis of the Adverse Effects of Ionizing Radiation Exposure on Cardiac Catheterization Staffs.Curr Radiopharm. 2024;17(3):219-228. doi: 10.2174/0118744710283181231229112417. Curr Radiopharm. 2024. PMID: 38314600 Review.
-
Physicians' radiation exposure in the catheterization lab: does the type of procedure matter?JACC Cardiovasc Interv. 2013 Oct;6(10):1095-102. doi: 10.1016/j.jcin.2013.05.012. JACC Cardiovasc Interv. 2013. PMID: 24156970
-
Reduction of radiation delivered to patients undergoing invasive coronary procedures. Effect of a programme for dose reduction based on radiation-protection training.Arch Cardiovasc Dis. 2009 Dec;102(12):821-7. doi: 10.1016/j.acvd.2009.09.007. Arch Cardiovasc Dis. 2009. PMID: 19963193
-
Dose to cardiologists in haemodynamic and electrophysiology cardiac interventional procedures.Radiat Prot Dosimetry. 2005;117(1-3):111-5. doi: 10.1093/rpd/nci764. Epub 2006 Feb 3. Radiat Prot Dosimetry. 2005. PMID: 16461486
Cited by
-
Relation between projection positions and X-ray radiation doses during placement of the coronary sinus mapping electrode.J Interv Card Electrophysiol. 2012 Sep;34(3):263-6. doi: 10.1007/s10840-012-9671-8. Epub 2012 Mar 15. J Interv Card Electrophysiol. 2012. PMID: 22415318
-
Fractional flow reserve, quantitative flow ratio, and instantaneous wave-free ratio: a comparison of the procedure-related dose of ionising radiation.Postepy Kardiol Interwencyjnej. 2021 Mar;17(1):33-38. doi: 10.5114/aic.2021.104765. Epub 2021 Mar 27. Postepy Kardiol Interwencyjnej. 2021. PMID: 33868415 Free PMC article.
-
Retrospective study of patients radiation dose during cardiac catheterization procedures.Br J Radiol. 2019 Jul;92(1099):20181021. doi: 10.1259/bjr.20181021. Epub 2019 May 14. Br J Radiol. 2019. PMID: 31045448 Free PMC article.
-
Utilization of an Optimized Radiation Strategy in Primary Percutaneous Coronary Intervention for Patients with ST-Segment-Elevation Myocardial Infarction.Cardiol Res Pract. 2019 Sep 2;2019:6094806. doi: 10.1155/2019/6094806. eCollection 2019. Cardiol Res Pract. 2019. PMID: 31565430 Free PMC article.
-
Minimizing Radiation in the Modern Electrophysiology Laboratory.J Innov Card Rhythm Manag. 2018 Aug 15;9(8):3265-3270. doi: 10.19102/icrm.2018.090805. eCollection 2018 Aug. J Innov Card Rhythm Manag. 2018. PMID: 32494501 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous