[Prostate localization systems for prostate radiotherapy]
- PMID: 17035061
- DOI: 10.1016/j.canrad.2006.09.002
[Prostate localization systems for prostate radiotherapy]
Abstract
The development of sophisticated conformal radiation therapy techniques for prostate cancer, such as intensity-modulated radiotherapy, implies precise and accurate targeting. Inter- and intrafraction prostate motion can be significant and should be characterized, unless the target volume may occasionally be missed. Indeed, bony landmark-based portal imaging does not provide the positional information for soft-tissue targets (prostate and seminal vesicles) or critical organs (rectum and bladder). In this article, we describe various prostate localization systems used before or during the fraction: rectal balloon, intraprostatic fiducials, ultrasound-based localization, integrated CT/linear accelerator system, megavoltage or kilovoltage cone-beam CT, Calypso 4D localization system tomotherapy, Cyberknife and Exactrac X-Ray 6D. The clinical benefit in using such prostate localization tools is not proven by randomized studies and the feasibility has just been established for some of these techniques. Nevertheless, these systems should improve local control by a more accurate delivery of an increased prescribed dose in a reduced planning target volume.
Similar articles
-
Magnetic resonance assessment of prostate localization variability in intensity-modulated radiotherapy for prostate cancer.Int J Radiat Oncol Biol Phys. 2004 Dec 1;60(5):1611-21. doi: 10.1016/j.ijrobp.2004.07.711. Int J Radiat Oncol Biol Phys. 2004. PMID: 15590193
-
Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.Med Dosim. 2009 Fall;34(3):256-60. doi: 10.1016/j.meddos.2008.10.005. Epub 2008 Dec 3. Med Dosim. 2009. PMID: 19647638
-
A phase II trial for the optimisation of treatment position in the radiation therapy of prostate cancer.Radiother Oncol. 2008 Jul;88(1):61-6. doi: 10.1016/j.radonc.2008.03.023. Epub 2008 Apr 29. Radiother Oncol. 2008. PMID: 18453021 Clinical Trial.
-
When should the seminal vesicles be included in the target volume in prostate radiotherapy?Clin Oncol (R Coll Radiol). 2007 Jun;19(5):302-7. doi: 10.1016/j.clon.2007.03.005. Epub 2007 Apr 19. Clin Oncol (R Coll Radiol). 2007. PMID: 17448647 Review.
-
Advances in the treatment of localized prostate cancer: the role of anatomic and functional imaging in men managed with radiotherapy.J Clin Oncol. 2007 Mar 10;25(8):987-95. doi: 10.1200/JCO.2006.10.3218. J Clin Oncol. 2007. PMID: 17350948 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical