Load dependence of left ventricular diastolic pressure-volume relations during short-term coronary artery occlusion
- PMID: 1703931
- DOI: 10.1161/01.cir.83.2.661
Load dependence of left ventricular diastolic pressure-volume relations during short-term coronary artery occlusion
Abstract
We evaluated the effect of altered loading conditions on left ventricular (LV) diastolic pressure-volume relations during acute coronary artery occlusion that was produced by inflation of an intracoronary balloon. Open-chest anesthetized dogs (n = 18) were instrumented so that LV pressure (micromanometer) and LV volume (conductance) could be measured without disturbing the pericardium. The effects of brief periods of occlusion (1-2 minutes) were assessed under steady-state conditions before and after dextran infusion with the pericardium present and absent and during vena caval occlusion. Under steady-state conditions before dextran infusion with the pericardium removed, at an LV end-diastolic pressure (EDP) of 8.4 +/- 1.4 mm Hg, occlusion resulted in a rightward shift in the diastolic portion of the LV pressure-volume loop (delta LVEDP, 2.7 +/- 2.3 mm Hg; delta LVEDV, 6.3 +/- 4.7 ml, both p less than 0.05 versus control). After dextran infusion (LVEDP, 20.9 +/- 6.0 mm Hg), occlusion resulted in a rightward and upward shift in the diastolic portion of the LV pressure-volume loop (delta LVEDP, 5.8 +/- 4.4 mm Hg; delta LVEDV, 4.2 +/- 3.0 ml, both p less than 0.05 versus control). At low cardiac volumes before dextran infusion, the intact pericardium did not affect the response to occlusion. By contrast, after dextran infusion in the presence of an intact pericardium, LVEDP significantly increased (delta, 6.4 +/- 3.6 mm Hg, p less than 0.05) but LVDEV did not (delta, 0.7 +/- 1.5 ml, p = NS). There was a parallel upward shift in the diastolic portion of the LV pressure-volume loop that was eliminated by removal of the pericardium. Thus, the change in LV diastolic pressure and volume during occlusion varied and depended on the baseline cardiac volume and presence of the pericardium. Before dextran infusion with the pericardium present and absent, coronary artery occlusion did not alter the LV diastolic chamber stiffness parameter, which was calculated from the diastolic interval of an averaged steady-state beat (0.040 +/- 0.019 versus 0.036 +/- 0.015 mm Hg/ml, p = NS). After dextran infusion with the pericardium present and absent, coronary artery occlusion increased the LV diastolic chamber stiffness parameter (0.057 +/- 0.034 and 0.074 +/- 0.034 mm Hg/ml, both p less than 0.05 versus controls, respectively). Vena caval occlusion eliminated the shifts in the diastolic portion of the LV pressure-volume loop with the pericardium present and absent.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
Influence of coronary occlusion during PTCA on end-systolic and end-diastolic pressure-volume relations in humans.Circulation. 1990 Feb;81(2):447-60. doi: 10.1161/01.cir.81.2.447. Circulation. 1990. PMID: 2297855
-
Comparative effects of pacing-induced and balloon coronary occlusion ischemia on left ventricular diastolic function in man.Circulation. 1991 Jul;84(1):211-22. doi: 10.1161/01.cir.84.1.211. Circulation. 1991. PMID: 2060097
-
Left ventricular contractility predicts how the end-diastolic pressure-volume relation shifts during pacing-induced ischemia in dogs.Circulation. 1995 May 1;91(9):2423-34. doi: 10.1161/01.cir.91.9.2423. Circulation. 1995. PMID: 7729030
-
Ventricular diastole and the role of the pericardium.Herz. 1990 Dec;15(6):354-61. Herz. 1990. PMID: 2279730 Review.
-
The pericardial hypothesis: a mechanism of acute shifts of the left ventricular diastolic pressure-volume relation.Clin Physiol. 1985 Oct;5(5):403-15. doi: 10.1111/j.1475-097x.1985.tb00771.x. Clin Physiol. 1985. PMID: 3931960 Review.
Cited by
-
Right ventricular dysfunction during coronary artery occlusion: pressure-volume analysis using conductance catheters during coronary angioplasty.Heart. 1997 Nov;78(5):480-7. doi: 10.1136/hrt.78.5.480. Heart. 1997. PMID: 9415008 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous