Abstract
The scoring artefact in the Farnsworth-Munsell 100-Hue test, arising from the grouping of the caps into four boxes, was investigated. The traditional method of scoring performed with the numbers of the anchor caps disregarded and the alternative scoring performed with the numbers of the anchor caps employed, were compared. For the traditional method of scoring, we revealed an increase of the error score of the outside (end-box) caps when the total error score was above 240. On the contrary for scoring performed with the numbers of the anchor caps employed, the difference between the error score of the outside caps and the average error per cap is not significant. To mitigate the end-box artefact and to improve the reliability of the Farnsworth-Munsell 100-Hue test, corrections to the traditional method of scoring are proposed.
Similar articles
-
A second box-end scoring artifact in the Farnsworth-Munsell 100-hue test.Invest Ophthalmol Vis Sci. 1993 Mar;34(3):503-6. Invest Ophthalmol Vis Sci. 1993. PMID: 8449669
-
An averaging method for the interpretation of the Farnsworth-Munsell 100-Hue Test--I. Congenital colour vision defects.Ophthalmic Physiol Opt. 1987;7(3):267-80. Ophthalmic Physiol Opt. 1987. PMID: 3500446
-
A method for increasing the scoring efficiency of the Farnsworth-Munsell 100-Hue test.Ophthalmic Physiol Opt. 1997 Mar;17(2):153-7. Ophthalmic Physiol Opt. 1997. PMID: 9196679
-
[The Farnsworth-Munsell 100 Hue test in the Bantu population. Preliminary results].J Fr Ophtalmol. 1994;17(11):664-7. J Fr Ophtalmol. 1994. PMID: 7722225 Review. French.
-
Review of the main colour vision clinical assessment tests.Arch Soc Esp Oftalmol (Engl Ed). 2019 Jan;94(1):25-32. doi: 10.1016/j.oftal.2018.08.006. Epub 2018 Oct 22. Arch Soc Esp Oftalmol (Engl Ed). 2019. PMID: 30361001 Review. English, Spanish.
Cited by
-
New iPAD-based test for the detection of color vision deficiencies.Graefes Arch Clin Exp Ophthalmol. 2018 Dec;256(12):2349-2360. doi: 10.1007/s00417-018-4154-y. Epub 2018 Oct 6. Graefes Arch Clin Exp Ophthalmol. 2018. PMID: 30291435
-
Antisaccade errors reveal cognitive control deficits in Parkinson's disease with freezing of gait.J Neurol. 2015 Dec;262(12):2745-54. doi: 10.1007/s00415-015-7910-5. Epub 2015 Oct 13. J Neurol. 2015. PMID: 26464101
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous