. 2006 Oct 17;48(8):1628-33.
doi: 10.1016/j.jacc.2006.05.071. Epub 2006 Sep 26.

Abnormal conduction increases risk of adverse outcomes from right ventricular pacing

Affiliations
Free article

Abnormal conduction increases risk of adverse outcomes from right ventricular pacing

John J Hayes et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: The purpose of this study was to determine whether QRS duration or morphology increased the risk of adverse outcome in the DAVID (Dual Chamber and VVI Implantable Defibrillator) trial.

Background: The DAVID trial found an increased risk of the combined end point of death and new or worsening congestive heart failure (CHF) in defibrillator recipients who were paced DDDR-70 versus VVI-40.

Methods: We analyzed the combined end point in patients with abnormal QRS duration (AbQRS) (> or =110 ms) compared with those with normal QRS duration (NQRS) (<110 ms).

Results: The QRS data were available for 496 of the 506 patients enrolled in the trial, including 223 patients with NQRS (45%) and 273 patients with AbQRS (55%). In patients in whom defibrillators were programmed to pace infrequently (VVI-40), having an NQRS or AbQRS was not an indicator of increased risk of adverse outcome. However, among patients in whom defibrillators were programmed in a manner that promoted more frequent ventricular pacing (DDDR-70), there was a significant adverse interaction with AbQRS; this combination was independently associated with a higher risk for developing CHF or death (p = 0.017).

Conclusions: Although patients with AbQRS tended to have other risk factors associated with poor outcome, the interaction of QRS duration with ventricular pacing (DDDR-70) independently contributed to a worse outcome and therefore, was a marker of patients in whom such treatment may be harmful. This should not imply that right ventricular pacing in NQRS patients is safe but rather that pacing in the context of an AbQRS is probably best avoided.