Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Nov;241(2):485-91.
doi: 10.1148/radiol.2412050800.

US appearance of the rotator cable with histologic correlation: preliminary results

Affiliations

US appearance of the rotator cable with histologic correlation: preliminary results

Yoav Morag et al. Radiology. 2006 Nov.

Abstract

Purpose: To characterize the ultrasonographic (US) appearance of the rotator cuff cable in asymptomatic shoulders and in cadaveric specimens, with histologic comparison for the latter.

Materials and methods: The cadaveric portion of this study was approved by the institution's Anatomical Donations Department. Institutional review board approval and informed consent were obtained from asymptomatic volunteers and clinical patients for the HIPAA-compliant portion of the study. Four fresh cadaveric shoulder specimens (two male subjects, 40 and 50 years old) were dissected, assessed for the presence of the rotator cable, and imaged with 12-MHz US. Histologic slides (hematoxylin-eosin stain) from three resected rotator cuff tendons were inspected for fibers in the expected location and orientation of the rotator cuff cable. The shoulders in 17 asymptomatic volunteers (seven men, two women; age range, 27-66 years; mean, 41 years) and contralateral asymptomatic shoulders in 10 patients (six men, four women; age range, 24-78 years; mean, 49 years) were scanned and evaluated for the presence and appearance of the rotator cable.

Results: The rotator cable was identified at gross dissection. Histologic examination and US of the cadaveric shoulders demonstrated an articular-sided fibrillar structure perpendicular to the rotator cuff tendon (average thickness and width, 1.2 mm and 4.5 mm, respectively). US of asymptomatic shoulders depicted a similar fibrillar structure in three (11%) shoulders up to 1.1-1.5 cm medial to the greater tuberosity (average thickness and width, 1.2 mm and 4.5 mm respectively).

Conclusion: The rotator cable can be depicted with US.

PubMed Disclaimer

LinkOut - more resources