A flow sensor suitable for use with split-flow ventilation--first preclinical data
- PMID: 17062113
- DOI: 10.1111/j.1525-1594.2006.00317.x
A flow sensor suitable for use with split-flow ventilation--first preclinical data
Abstract
Volutrauma caused by artificial ventilation represents a major morbidity risk for premature infants. Our working group has recently developed an innovative "split-flow ventilation" system aiming at the reduction of tidal volumes (TVs). The main problem for the practical use of this system is the fact that conventional measurements of commercially available flow sensors are distorted by the split flow. In this study, we present the first preclinical data from testing an adapted flow sensor combination recognizing the split flow. A preterm infant test lung was conventionally ventilated, modified by insertion of a split-flow line. In addition to the customary flow sensor (FS-1), a second flow sensor (FS-2) was integrated into the split-flow line, and a third (FS-3) was placed at the exit of the test lung for reference measurements. The signals of all three flow sensors were read and processed by a computer. The program was set to graphically add up flow curves 1, 2, and 3 during one ventilation loop. After 10 runs, a mean curve of FS-1+2 was calculated and compared to the mean curve of FS-3. Furthermore, the mean TV of 10 runs measured by FS-1+2 was calculated and compared with the mean TV calculated by FS-3. The summation curve FS-1+2 proved identical to the reference curve FS-3. FS-1+2 yielded a TV of 6.6 +/- 0.01 mL (inspiratory) and 6.7 +/- 0.02 mL (expiratory). The corresponding values of FS-3 were 6.5 +/- 0.20 mL and 6.6 +/- 0.09 mL, respectively. According to our results, the presented flow sensor constellation allows exact flow measurements in the experimental setting and appears suitable for usage in a split-flow ventilation circuit under clinical conditions.
Similar articles
-
The impact of instrumental dead-space in volume-targeted ventilation of the extremely low birth weight (ELBW) infant.Pediatr Pulmonol. 2009 Feb;44(2):128-33. doi: 10.1002/ppul.20954. Pediatr Pulmonol. 2009. PMID: 19061234
-
Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?Anesth Analg. 2008 May;106(5):1392-400, table of contents. doi: 10.1213/ane.0b013e31816a68c6. Anesth Analg. 2008. PMID: 18420850
-
Elimination of ventilator dead space during synchronized ventilation in premature infants.J Pediatr. 2003 Sep;143(3):315-20. doi: 10.1067/S0022-3476(03)00299-3. J Pediatr. 2003. PMID: 14517512
-
State of the art in conventional mechanical ventilation.J Perinatol. 2009 Apr;29(4):262-75. doi: 10.1038/jp.2009.11. Epub 2009 Feb 26. J Perinatol. 2009. PMID: 19242486 Review.
-
Monitoring respiratory mechanics during mechanical ventilation: where do the signals come from?Respir Care. 2005 Jan;50(1):28-52; discussion 52-4. Respir Care. 2005. PMID: 15636644 Review.
Cited by
-
Dead space washout by intentional leakage flow during conventional ventilation of premature infants-an experimental study.Pediatr Pulmonol. 2022 Sep;57(9):1998-2002. doi: 10.1002/ppul.25906. Epub 2022 Jun 20. Pediatr Pulmonol. 2022. PMID: 35355449 Free PMC article.
-
40 years neonatology : An academic life.Wien Klin Wochenschr. 2025 Feb;137(3-4):69-78. doi: 10.1007/s00508-024-02360-2. Epub 2024 Apr 18. Wien Klin Wochenschr. 2025. PMID: 38634910 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical