Finite element analysis and stent design: Reduction of dogboning
- PMID: 17065746
Finite element analysis and stent design: Reduction of dogboning
Abstract
In Western countries, cardiovascular disease is the most common cause of death, often related to atherosclerosis. This paper offers a brief introduction into some aspects of this disease and its treatment, where the use of stents is gaining increasing importance. Stents are supporting - mostly metal - tubular mesh structures which are opened in an obstructed artery in order to reopen it, and to offer radial strength to prevent elastic recoil of the dilated vessel. In addition to a variety of experimental tests to study the behavior of (new) stent designs, advanced numerical models (e.g. Finite Element Models) may offer interesting insights in the mechanical behavior of stents and will undoubtedly influence the design of future generation stents. A brief literature review on numerical studies dealing with the mechanical behavior of stents is presented. Subsequently, the finite element method is exploited to investigate and compare different designs of a "first generation" Palmaz Schatz stent in order to reduce the dogboning (i.e. ends of stent open first during expansion) to a minimum. Our computational models (Abaqus ) are described in terms of geometry, constitutive material models, numerical aspects and output quantities. Altering the original symmetric stent design to asymmetric designs decreased the dogboning from 27.24% to less than 10% for the vast majority of the studied asymmetric designs. For one particular configuration, the dogboning effect vanished completely. For this reason, taking asymmetry into account in the design of stents seems very promising, at least from the perspective of dogboning. However, as the dogboning only takes into account the radii (R) at the central and distal part of the stent, nothing can be concluded concerning the uniformity of the complete stent expansion. The mean value (Rm) and the root mean square (R(RMS)) of radii (differences) of the stent at the end of the loading phase (P = 0.7 N/mm2) are much better parameters to give a clear indication of the uniformity of the expanded stent's shape. Although the model is suitable to study basic aspects of stent deployment, further research is necessary, especially accounting for newer generation stent geometries and more realistic balloon-stent interaction.
Similar articles
-
Realistic finite element-based stent design: the impact of balloon folding.J Biomech. 2008;41(2):383-9. doi: 10.1016/j.jbiomech.2007.08.014. Epub 2007 Oct 24. J Biomech. 2008. PMID: 17920068
-
Cardiovascular stent design and vessel stresses: a finite element analysis.J Biomech. 2005 Aug;38(8):1574-81. doi: 10.1016/j.jbiomech.2004.07.022. J Biomech. 2005. PMID: 15958213
-
Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion.Ann Biomed Eng. 2008 Jul;36(7):1118-29. doi: 10.1007/s10439-008-9504-1. Epub 2008 Apr 24. Ann Biomed Eng. 2008. PMID: 18437572
-
Drug-eluting stents.Arch Cardiol Mex. 2006 Jul-Sep;76(3):297-319. Arch Cardiol Mex. 2006. PMID: 17091802 Review.
-
Endovascular device design in the future: transformation from trial and error to computational design.J Endovasc Ther. 2009 Feb;16 Suppl 1:I12-21. doi: 10.1583/08-2640.1. J Endovasc Ther. 2009. PMID: 19317584 Review.
Cited by
-
Fatigue life analysis and experimental verification of coronary stent.Heart Vessels. 2010 Jul;25(4):333-7. doi: 10.1007/s00380-009-1203-9. Epub 2010 Jul 31. Heart Vessels. 2010. PMID: 20676843
-
Multi-Objective Optimizations of Biodegradable Polymer Stent Structure and Stent Microinjection Molding Process.Polymers (Basel). 2017 Jan 17;9(1):20. doi: 10.3390/polym9010020. Polymers (Basel). 2017. PMID: 30970706 Free PMC article.
-
Silk-based biomaterials in biomedical textiles and fiber-based implants.Adv Healthc Mater. 2015 Jun 3;4(8):1134-51. doi: 10.1002/adhm.201500002. Epub 2015 Mar 13. Adv Healthc Mater. 2015. PMID: 25772248 Free PMC article.
-
Simulation of stent deployment in a realistic human coronary artery.Biomed Eng Online. 2008 Aug 6;7:23. doi: 10.1186/1475-925X-7-23. Biomed Eng Online. 2008. PMID: 18684321 Free PMC article.
-
Optimizing through computational modeling to reduce dogboning of functionally graded coronary stent material.J Mater Sci Mater Med. 2017 Aug 17;28(9):142. doi: 10.1007/s10856-017-5959-7. J Mater Sci Mater Med. 2017. PMID: 28819891
MeSH terms
LinkOut - more resources
Full Text Sources