Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Sep-Oct;21(5):769-76.

Short dental implants as a treatment option: results from an observational study in a single private practice

Affiliations
  • PMID: 17066639
Comparative Study

Short dental implants as a treatment option: results from an observational study in a single private practice

Murray L Arlin. Int J Oral Maxillofac Implants. 2006 Sep-Oct.

Abstract

Purpose: The purpose was to evaluate clinical outcome of short (6- and 8-mm) dental implants placed in sites with low bone availability (7 to 11 mm) in a single private practice and to compare their survival with that of longer implants.

Materials and methods: Implants were placed by a single private practitioner in a variety of clinical indications. Exclusion criteria included uncontrolled diabetes mellitus, alcoholism, and systemic immune disorders. Clinical data relating to implant placement and follow-up appointments, including adverse events, were entered into an electronic database. Two-year survival rates were calculated and life table analyses undertaken for implants measuring 6, 8, and 10 to 16 mm.

Results: A total of 630 Straumann implants were placed in 264 patients between April 1994 and December 2003. Of these, 35 implants were 6 mm long, 141 were 8 mm long, and 454 were 10 to 16 mm long. Maximum follow-up was 64.6 months, 83.7 months, and 102 months for implants measuring 6 mm, 8 mm, and 10 to 16 mm, respectively. Two-year survival rates were 94.3%, 99.3%, and 97.4% for 6-mm, 8-mm, and 10- to 16-mm implants, respectively.

Discussion: The results indicated that the 2-year outcome for 6-mm and 8-mm implants was comparable to that for longer (10- to 16-mm) implants in this patient population.

Conclusion: In this study, short (6- or 8-mm) implants were used with good reliability in patients with limited bone availability, without the need for ridge augmentation. Shorter implant length was not associated with reduced survival at 2 years, compared with longer implants.

PubMed Disclaimer

Substances

LinkOut - more resources