Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006;18(6):340-50; discussion 351.
doi: 10.1111/j.1708-8240.2006.00046.x.

Clinically relevant issues related to preheating composites

Affiliations

Clinically relevant issues related to preheating composites

Márcia Daronch et al. J Esthet Restor Dent. 2006.

Abstract

Statement of the problem: Issues regarding the use of composite preheating need to be investigated so that the clinician will better understand the variables associated with this method.

Purpose: To examine the multiple aspects of use of a commercial composite preheating device (Calset, AdDent Inc., Danbury, CT, USA).

Materials and methods: Temperature values of three heating units and composite compules were obtained using a K-type thermocouple and were recorded digitally in real time. The following parameters were measured: maximum heater and composite temperature and its stability upon storage, composite temperature change when removed from the heater and injected, the effect of delivery system on ejected composite temperature, and the effect of repeated and extended preheating on composite monomer conversion (using infrared spectroscopy). Monomer conversion was measured after repeated composite cycling (from room temperature [RT] to 60 degrees C, 10x) or extended preheating (24 hours at 60 degrees C), and values were compared with composite maintained at RT (control group). Among test parameters, data (N=5 for each parameter) were analyzed using Student's t-test, analysis of variance, and the Tukey-Kramer post-hoc test where appropriate (alpha=0.05).

Results/conclusions: Two of the three tested units achieved the stated preset temperatures. Composite attained temperature values close to the heating unit. Composite temperature drop upon removal from the heater was dramatic: within 2 minutes a 50% temperature drop was noted. Heating the compule while preloaded in the syringe provided higher delivery temperatures than heating the compule separately (p < 0.00). Optimum results were achieved when preheated composite was dispensed and used as quickly as possible. Neither repeated nor extended preheating of composite significantly affected monomer conversion.

Clinical significance: Preheating composite has potential benefits, but should be used with knowledge of its limitations. Reheating of unused composite does not affect its degree of conversion, thus decreasing material waste. Heating of the composite preloaded in the delivery syringe enhances the temperature of extruded composite.

PubMed Disclaimer

Comment in

  • Critical appraisal: preheating composites.
    da Costa JB, Hilton TJ, Swift EJ Jr. da Costa JB, et al. J Esthet Restor Dent. 2011 Aug;23(4):269-75. doi: 10.1111/j.1708-8240.2011.00461.x. Epub 2011 Jun 22. J Esthet Restor Dent. 2011. PMID: 21806761

Publication types

MeSH terms

LinkOut - more resources