Abstract
Recent studies have shown all-arthroscopic rotator cuff repairs to have comparable clinical results to mini-open or open repairs. Previous drawbacks to arthroscopic repair have included not being able to place a modified Mason-Allen stitch with a suture anchor technique. We present a technique using the Arthrex Scorpion device (Arthrex, Naples, FL) to place a modified Mason-Allen stitch arthroscopically via a double-loaded FiberWire metal suture anchor (Arthrex). The Scorpion suture passer places a stitch from inferior to superior through the torn rotator cuff. The suture is grabbed and reloaded into the Scorpion device. The device is then turned upside down, and a horizontal stitch is placed from superior to inferior. The stitch is retrieved again and reloaded a third time. The last pass is placed so that the final stitch passes anterior to the inferior suture but beyond the previously placed horizontal mattress stitch. This effectively reproduces the described biomechanically superior modified Mason-Allen stitch.
Similar articles
-
Mechanical strength of arthroscopic rotator cuff repair techniques: an in vitro study.J Bone Joint Surg Am. 2002 Dec;84(12):2152-60. doi: 10.2106/00004623-200212000-00005. J Bone Joint Surg Am. 2002. PMID: 12473702
-
Modified Mason-Allen suture bridge technique: a new suture bridge technique with improved tissue holding by the modified Mason-Allen stitch.Clin Orthop Surg. 2012 Sep;4(3):242-5. doi: 10.4055/cios.2012.4.3.242. Epub 2012 Aug 14. Clin Orthop Surg. 2012. PMID: 22949957 Free PMC article.
-
Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch).Arthroscopy. 2007 Apr;23(4):440.e1-4. doi: 10.1016/j.arthro.2006.07.046. Arthroscopy. 2007. PMID: 17418339
-
The evolution of suture anchors in arthroscopic rotator cuff repair.Arthroscopy. 2013 Sep;29(9):1589-95. doi: 10.1016/j.arthro.2013.05.011. Epub 2013 Jul 19. Arthroscopy. 2013. PMID: 23876609 Review.
-
Does Suture Technique Affect Re-Rupture in Arthroscopic Rotator Cuff Repair? A Meta-analysis.Arthroscopy. 2015 Aug;31(8):1576-82. doi: 10.1016/j.arthro.2015.02.004. Epub 2015 Mar 29. Arthroscopy. 2015. PMID: 25828166
Cited by
-
Stress distribution inside bone after suture anchor insertion: simulation using a three-dimensional finite element method.Knee Surg Sports Traumatol Arthrosc. 2013 Aug;21(8):1777-82. doi: 10.1007/s00167-012-2060-0. Epub 2012 May 24. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 22622782
-
Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?Knee Surg Sports Traumatol Arthrosc. 2010 Dec;18(12):1718-29. doi: 10.1007/s00167-010-1245-7. Epub 2010 Aug 25. Knee Surg Sports Traumatol Arthrosc. 2010. PMID: 20737134
-
Comparison between four different suture configurations for rotator cuff repair: a biomechanical animal study.SICOT J. 2024;10:39. doi: 10.1051/sicotj/2024038. Epub 2024 Oct 7. SICOT J. 2024. PMID: 39374408 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical