Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Jan;242(1):137-43.
doi: 10.1148/radiol.2421060093. Epub 2006 Nov 7.

Lymph node metastasis: ultrasmall superparamagnetic iron oxide-enhanced MR imaging versus PET/CT in a rabbit model

Affiliations

Lymph node metastasis: ultrasmall superparamagnetic iron oxide-enhanced MR imaging versus PET/CT in a rabbit model

Seung Hong Choi et al. Radiology. 2007 Jan.

Abstract

Purpose: To prospectively compare the diagnostic accuracy of ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging and integrated positron emission tomography-computed tomography (PET/CT) for the depiction of lymph node metastasis in an animal model, with histologic findings as the reference standard.

Materials and methods: This experiment was approved by the local animal care committee. VX2 carcinoma was implanted into the thighs of 11 rabbits 4 weeks before the imaging study. T2- and T2*-weighted MR examinations were performed 24 hours after USPIO administration, followed by integrated PET/CT. USPIO-enhanced MR imaging and PET/CT analysis for the evaluation of the presence of metastasis in iliac lymph nodes were performed independently by two radiologists and two nuclear medicine physicians, respectively, without histopathologic knowledge. Results were evaluated by using receiver operating characteristic (ROC) analysis, and sensitivities and specificities were compared by using a Z test.

Results: Metastases were histopathologically confirmed in 22 of 62 iliac lymph nodes. USPIO-enhanced MR imaging showed a significantly greater area under the ROC curve than did PET/CT (0.984 vs 0.852; P=.023). The respective sensitivity and specificity for the detection of lymph node metastasis were 91% (20 of 22) and 95% (38 of 40) for USPIO-enhanced MR imaging and 64% (14 of 22) and 98% (39 of 40) for PET/CT. In terms of sensitivity, a significant difference was found between USPIO-enhanced MR imaging and PET/CT, particularly for nodal metastasis of less than 5 mm (86% [six of seven] vs 0% [zero of seven]; P=.031), whereas the specificity of the two imaging modalities was similar (P=.226).

Conclusion: USPIO-enhanced MR imaging results in higher diagnostic accuracy for depicting lymph node metastasis than does PET/CT.