Fluorescence lifetime imaging microscopy: two-dimensional distribution measurement of fluorescence lifetime
- PMID: 17110215
- DOI: 10.1016/S0076-6879(06)14033-1
Fluorescence lifetime imaging microscopy: two-dimensional distribution measurement of fluorescence lifetime
Abstract
A newly developed fluorescence lifetime imaging microscopy (FLIM) system has combined the high-temporal resolution of a streak camera with the high-spatial resolution of a microscope to obtain a two-dimensional distribution of fluorescence lifetimes within living cells. The temporal resolution is as short as 20 ps. The effective field of view is 48 x 45 mum with 0.2 mum resolution using a 60x water immersion objective. Image acquisition time is as short as 3 s per image. Measured and published values of lifetime for standard fluophores are shown with good agreement. Examples of FLIM and fluorescence resonance energy transfer images are presented.
Similar articles
-
Optimized protocol of a frequency domain fluorescence lifetime imaging microscope for FRET measurements.Microsc Res Tech. 2009 May;72(5):371-9. doi: 10.1002/jemt.20665. Microsc Res Tech. 2009. PMID: 19084885
-
Detection of the interaction between SNAP25 and rabphilin in neuroendocrine PC12 cells using the FLIM/FRET technique.Microsc Res Tech. 2008 Jan;71(1):26-34. doi: 10.1002/jemt.20521. Microsc Res Tech. 2008. PMID: 17886343
-
In-depth fluorescence lifetime imaging analysis revealing SNAP25A-Rabphilin 3A interactions.Microsc Microanal. 2008 Dec;14(6):507-18. doi: 10.1017/S1431927608080628. Microsc Microanal. 2008. PMID: 18986604
-
Advances in cellular, subcellular, and nanoscale imaging in vitro and in vivo.Cytometry A. 2010 Jul;77(7):667-76. doi: 10.1002/cyto.a.20931. Cytometry A. 2010. PMID: 20564541 Review.
-
Imaging spatiotemporal dynamics of neuronal signaling using fluorescence resonance energy transfer and fluorescence lifetime imaging microscopy.Curr Opin Neurobiol. 2006 Oct;16(5):551-61. doi: 10.1016/j.conb.2006.08.012. Epub 2006 Sep 12. Curr Opin Neurobiol. 2006. PMID: 16971112 Review.
Cited by
-
Spatio-Temporal Quantification of FRET in living cells by fast time-domain FLIM: a comparative study of non-fitting methods [corrected].PLoS One. 2013 Jul 18;8(7):e69335. doi: 10.1371/journal.pone.0069335. Print 2013. PLoS One. 2013. PMID: 23874948 Free PMC article.
-
Biophysical aspects of biomineralization.Biophys Rev. 2017 Oct;9(5):747-760. doi: 10.1007/s12551-017-0315-1. Epub 2017 Aug 29. Biophys Rev. 2017. PMID: 28852989 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources