Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study
- PMID: 17110872
- DOI: 10.1097/01.CCM.0000251131.40301.E2
Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study
Abstract
Objective: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung.
Design: Prospective laboratory animal investigation.
Setting: Clinical physiology research laboratory, University of Uppsala, Sweden.
Subjects: Eight pigs submitted to repeated lung lavages.
Interventions: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans.
Measurements and main results: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition.
Conclusions: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.
Similar articles
-
Hemodynamic and respiratory changes during lung recruitment and descending optimal positive end-expiratory pressure titration in patients with acute respiratory distress syndrome.Crit Care Med. 2007 Mar;35(3):787-93. doi: 10.1097/01.CCM.0000257330.54882.BE. Crit Care Med. 2007. PMID: 17255855 Clinical Trial.
-
Relationship between dynamic respiratory mechanics and disease heterogeneity in sheep lavage injury.Crit Care Med. 2007 Mar;35(3):870-8. doi: 10.1097/01.CCM.0000257331.42485.94. Crit Care Med. 2007. PMID: 17255854
-
Dynamic versus static respiratory mechanics in acute lung injury and acute respiratory distress syndrome.Crit Care Med. 2006 Aug;34(8):2090-8. doi: 10.1097/01.CCM.0000227220.67613.0D. Crit Care Med. 2006. PMID: 16755254
-
Using pressure-volume curves to set proper PEEP in acute lung injury.Nurs Crit Care. 2007 Sep-Oct;12(5):231-41. doi: 10.1111/j.1478-5153.2007.00224.x. Nurs Crit Care. 2007. PMID: 17883616 Review.
-
The use of positive end-expiratory pressure in the management of the acute respiratory distress syndrome.Minerva Anestesiol. 2005 Jun;71(6):265-72. Minerva Anestesiol. 2005. PMID: 15886587 Review.
Cited by
-
Positive end-expiratory pressure at minimal respiratory elastance represents the best compromise between mechanical stress and lung aeration in oleic acid induced lung injury.Crit Care. 2007;11(4):R86. doi: 10.1186/cc6093. Crit Care. 2007. PMID: 17688701 Free PMC article.
-
Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.Crit Care. 2011 Aug 11;15(4):R193. doi: 10.1186/cc10354. Crit Care. 2011. PMID: 21834953 Free PMC article.
-
Real-time images of tidal recruitment using lung ultrasound.Crit Ultrasound J. 2015 Dec;7(1):19. doi: 10.1186/s13089-015-0036-2. Epub 2015 Dec 12. Crit Ultrasound J. 2015. PMID: 26660526 Free PMC article.
-
Monitoring of lung function in acute respiratory distress syndrome.Ann Transl Med. 2017 Jul;5(14):284. doi: 10.21037/atm.2017.06.56. Ann Transl Med. 2017. PMID: 28828359 Free PMC article. Review.
-
Integrated EIT system for functional lung ventilation imaging.Biomed Eng Online. 2019 Jul 25;18(1):83. doi: 10.1186/s12938-019-0701-y. Biomed Eng Online. 2019. PMID: 31345220 Free PMC article.