Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Dec;44(12):1093-104.
doi: 10.1007/s11517-006-0125-2. Epub 2006 Nov 17.

Automatic user customization for improving the performance of a self-paced brain interface system

Affiliations

Automatic user customization for improving the performance of a self-paced brain interface system

Mehrdad Fatourechi et al. Med Biol Eng Comput. 2006 Dec.

Abstract

Customizing the parameter values of brain interface (BI) systems by a human expert has the advantage of being fast and computationally efficient. However, as the number of users and EEG channels grows, this process becomes increasingly time consuming and exhausting. Manual customization also introduces inaccuracies in the estimation of the parameter values. In this paper, the performance of a self-paced BI system whose design parameter values were automatically user customized using a genetic algorithm (GA) is studied. The GA automatically estimates the shapes of movement-related potentials (MRPs), whose features are then extracted to drive the BI. Offline analysis of the data of eight subjects revealed that automatic user customization improved the true positive (TP) rate of the system by an average of 6.68% over that whose customization was carried out by a human expert, i.e., by visually inspecting the MRP templates. On average, the best improvement in the TP rate (an average of 9.82%) was achieved for four individuals with spinal cord injury. In this case, the visual estimation of the parameter values of the MRP templates was very difficult because of the highly noisy nature of the EEG signals. For four able-bodied subjects, for which the MRP templates were less noisy, the automatic user customization led to an average improvement of 3.58% in the TP rate. The results also show that the inter-subject variability of the TP rate is also reduced compared to the case when user customization is carried out by a human expert. These findings provide some primary evidence that automatic user customization leads to beneficial results in the design of a self-paced BI for individuals with spinal cord injury.

PubMed Disclaimer

Similar articles

Cited by

References

    1. IEEE Trans Biomed Eng. 2004 Jun;51(6):985-92 - PubMed
    1. Electromyogr Clin Neurophysiol. 1994 Jan-Feb;34(1):5-13 - PubMed
    1. Med Biol Eng Comput. 2003 Jan;41(1):85-93 - PubMed
    1. IEEE Trans Rehabil Eng. 2000 Jun;8(2):180-5 - PubMed
    1. IEEE Trans Biomed Eng. 2000 Oct;47(10):1297-307 - PubMed

Publication types

LinkOut - more resources