Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Apr;245(4):511-5.
doi: 10.1007/s00417-006-0434-z. Epub 2006 Nov 17.

Correlation between optic disc area and retinal nerve fiber layer thickness: a study on scanning laser polarimetry with variable corneal compensation

Affiliations

Correlation between optic disc area and retinal nerve fiber layer thickness: a study on scanning laser polarimetry with variable corneal compensation

Stefano Da Pozzo et al. Graefes Arch Clin Exp Ophthalmol. 2007 Apr.

Abstract

Purpose: To evaluate if a significant increase of the peripapillary retinal nerve fiber layer (RNFL) thickness can be measured in a sample of healthy eyes by means of scanning laser polarimetry with variable corneal compensation (GDx-VCC) as the optic disc (OD) area increases.

Methods: One eye each of 232 healthy subjects (mean age: 57.8 years; range:40-70) was considered. Temporal-superior-nasal-inferior-temporal average (TSNIT Avg) and OD area (area within the ellipse placed on inner border of peripapillary scleral ring) values were collected. Ellipse horizontal and vertical diameters provided on printout were used to estimate OD area using the equation: OD area = pi x horizontal radius x vertical radius. TSNIT Avg values were plotted against OD area and a multiple linear regression including age calculated.

Results: Mean OD area was 2.19 mm(2)+/-0.45 (range: 1.23-3.59) and mean TSNIT Avg was 54.3 micro +/- 3.2 (range: 45.8-61.8). Multiple linear regression equation was TSNIT Avg=57.7-0.096 x OD Area-0.055 x Age (Pearson r=-0.146: p=0.086)

Conclusion: In our sample of healthy eyes, no significant correlation was found between TSNIT Avg and OD area. In spite of a shorter distance between OD and measurement ellipse margins, larger discs did not necessarily show a thicker RNFL. Probably the large inter-subject variability for RNFL thickness, and then for axonal count, was a predominant factor over OD area.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Br J Ophthalmol. 1997 Dec;81(12):1046-9 - PubMed
    1. Ophthalmic Res. 1988;20(5):298-303 - PubMed
    1. Eur J Ophthalmol. 2005 May-Jun;15(3):360-6 - PubMed
    1. Am J Ophthalmol. 1987 Apr 15;103(4):497-504 - PubMed
    1. Arch Ophthalmol. 1980 Sep;98(9):1630-6 - PubMed

LinkOut - more resources