Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Nov 21;48(10):1946-50.
doi: 10.1016/j.jacc.2006.07.055. Epub 2006 Oct 31.

Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography

Affiliations
Free article

Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography

Hajime Sakuma et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease.

Background: The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients.

Methods: Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm.

Results: The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%).

Conclusions: Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources