Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Dec;46(4):585-9.

The reliability of isokinetic and isometric leg strength measures among individuals with symptoms of mild osteoarthritis

Affiliations
  • PMID: 17119524

The reliability of isokinetic and isometric leg strength measures among individuals with symptoms of mild osteoarthritis

M R Carpenter et al. J Sports Med Phys Fitness. 2006 Dec.

Abstract

Aim: The aim of the study is to evaluate the test-retest reliability of measures of isokinetic and isometric leg strength and joint function among individuals exhibiting symptoms of mild osteoarthritis. Reliable procedures are needed to assess the effectiveness of an intervention on osteoarthritic symptoms.

Methods: Test-retest reliability of two leg strength protocols was assessed using the intraclass correlation coefficient (R). Testing was completed on two occasions separated by 7 days. Eighteen subjects (9 male and 9 female; 54.1+/-11 years) completed an isokinetic testing trial, which consisted of a set of 5 maximal repetitions of the quadriceps and hamstrings at 60 deg/s followed by a set of 15 maximal contractions at 180 deg/s with a 2-min rest between sets and an isometric testing trial, which consist of 3 maximal contractions of the quadriceps for 6 s with a 30-s rest between contractions at 30, 45, and 80 degrees of knee flexion for a total of 9 isometric contractions. A 90-s rest occurred between angles.

Results: Most of the isokinetic variables showed moderate to high intraclass reliability (ICC). Two of the calculated isokinetic variables (work fatigue at 180 degrees /s for extension and for flexion) showed low intraclass reliability (ICC=0.78, resp. ICC=0.6). All calculated ICC values of the isometric variables were moderate to high.

Conclusions: Test-retest reliability of isokinetic and isometric leg strength was high, allowing the intervention protocol to monitor changes in leg strength and joint function among those exhibiting symptoms of mild osteoarthritis.

PubMed Disclaimer

Publication types