Randomized Controlled Trial
. 2007 May;91(5):644-8.
doi: 10.1136/bjo.2006.103648. Epub 2006 Nov 23.

Influence of three-piece and single-piece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial

Affiliations
Randomized Controlled Trial

Influence of three-piece and single-piece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial

Reda Zemaitiene et al. Br J Ophthalmol. 2007 May.

Abstract

Background: Posterior capsule opacification (PCO) is still a major long-term complication of modern cataract surgery. We evaluated the impact of sharp-edged intraocular lenses (IOLs) with different haptic designs made from the same hydrophobic acrylic material on posterior and anterior lens capsule opacification.

Setting: Eye clinic of Kaunas University of Medicine, Lithuania. Prospective randomised clinical study.

Methods: Seventy-four eyes of 74 patients scheduled for cataract surgery were included in a prospective randomised clinical study. Thirty-seven eyes of 37 patients received a three-piece acrylic hydrophobic (AcrySof, MA3OBA, Alcon) IOL; and thirty-seven eyes of 37 patients received a one-piece acrylic hydrophobic (AcrySof, SA3OAL, Alcon) IOL. Visual acuity, anterior capsule opacification (ACO), capsular folds, capsulorrhexis/optic overlapping and posterior capsule opacification (PCO) were evaluated. ACO was assessed subjectively. PCO values in the entire IOL optic area and in the central 3 mm optic zone were assessed using a photographic image-analysis system (EPCO2000). Follow-ups were performed postoperatively at 1 day, 6 months, 1 year and 2 years.

Results: There were no significant differences in best corrected visual acuity, grade of ACO and capsulorrhexis/optic overlapping between IOL types during the follow-up period. Patients in the one-piece acrylic hydrophobic IOL group more frequently presented with capsular folds behind the IOL optic area than those in the three-piece IOL group. In the three-piece acrylic hydrophobic IOL group, PCO values (mean (SD)) of the entire IOL optic area were significantly lower six months postoperative (three-piece: 0.002 (0.009); one-piece: 0.007 (0.017); p=0.04), one year postoperative (three-piece: 0.004 (0.016); one-piece: 0.026 (0.041); p=0.001) as well as one year postoperative in the central 3 mm optic zone (three-piece: 0.000 (0.0002); one-piece: 0.019 (0.049); p=0.001). However, two years postoperative, the PCO values of the groups did not show significant differences (entire IOL optic area: three-piece, 0.136 (0.223); one-piece, 0.154 (0.190); p=0.18; central zone: three-piece, 0.023 (0.065); one-piece: 0.020 (0.039); p=0.44).

Conclusion: The 2 year follow-up after cataract surgery showed no significant difference in ACO and PCO development between three-piece and one-piece acrylic hydrophobic intraocular lenses.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None.

References

    1. Apple D J, Solomon K D, Tetz M R.et al Posterior capsule opacification. Major review. Surv Ophthalmol 19923773–105. - PubMed
    1. Schaumberg D A, Dana M R, Christen W G.et al A systematic overview of the incidence of posterior capsule opacification. Ophthalmology 19981051213–1221. - PubMed
    1. Apple D J, Peng Q, Visessook N.et al Eradication of posterior capsule opacification. Documentation of a marked decrease in Nd: YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem, Ophthalmology 2001108505–518. - PubMed
    1. Nishi O, Nishi K, Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers 199829587–594. - PubMed
    1. Ursell P G, Spalton D J, Pande M V.et al Relationship between intraocular lens biomaterials and posterior capsule opacification. J Cataract Refract Surg 199824352–360. - PubMed

Publication types