Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses
Abstract
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.
Copyright (c) 2006 John Wiley & Sons, Ltd.
Similar articles
-
Coupling of protein HPLC to MALDI-TOF MS using an on-target device for fraction collection, concentration, digestion, desalting, and matrix/analyte cocrystallization.Anal Chem. 2007 Mar 1;79(5):2058-66. doi: 10.1021/ac061919p. Epub 2007 Jan 26. Anal Chem. 2007. PMID: 17256876
-
Improved peptide mass fingerprinting matches via optimized sample preparation in MALDI mass spectrometry.Anal Chim Acta. 2008 Oct 3;627(1):162-8. doi: 10.1016/j.aca.2008.05.059. Epub 2008 Jun 12. Anal Chim Acta. 2008. PMID: 18790140
-
Experimental evaluation of protein identification by an LC/MALDI/on-target digestion approach.J Proteome Res. 2008 Sep;7(9):3697-707. doi: 10.1021/pr800258k. Epub 2008 Jul 3. J Proteome Res. 2008. PMID: 18597512
-
How to make big molecules fly out of liquid water: applications, features and physics of laser assisted liquid phase dispersion mass spectrometry.Phys Chem Chem Phys. 2007 Jul 14;9(26):3335-60. doi: 10.1039/b615114k. Epub 2007 Mar 27. Phys Chem Chem Phys. 2007. PMID: 17664960 Review.
-
Application of new analytical technology to the production of a "well-characterized biological".Dev Biol Stand. 1998;96:11-25. Dev Biol Stand. 1998. PMID: 9890511 Review.
Cited by
-
A novel "reactomics" approach for cancer diagnostics.Sensors (Basel). 2012;12(5):5572-85. doi: 10.3390/s120505572. Epub 2012 May 2. Sensors (Basel). 2012. PMID: 22778601 Free PMC article.
-
Diagnostic and prognostic role of serum protein peak at 6449 m/z in gastric adenocarcinoma based on mass spectrometry.Br J Cancer. 2016 Apr 12;114(8):929-38. doi: 10.1038/bjc.2016.52. Epub 2016 Mar 22. Br J Cancer. 2016. PMID: 27002935 Free PMC article.
-
Comparative proteomic analysis of serum diagnosis patterns of sputum smear-positive pulmonary tuberculosis based on magnetic bead separation and mass spectrometry analysis.Int J Clin Exp Med. 2015 Feb 15;8(2):2077-85. eCollection 2015. Int J Clin Exp Med. 2015. PMID: 25932138 Free PMC article.
-
Serum apolipoproteins C-I and C-III are reduced in stomach cancer patients: results from MALDI-based peptidome and immuno-based clinical assays.PLoS One. 2011 Jan 18;6(1):e14540. doi: 10.1371/journal.pone.0014540. PLoS One. 2011. PMID: 21267442 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources