Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2006 Nov;178(11):1086-94.
doi: 10.1055/s-2006-926957.

[Modern diagnostic assessment of the upper urinary tract using multislice CT urography]

[Article in German]
Affiliations
Review

[Modern diagnostic assessment of the upper urinary tract using multislice CT urography]

[Article in German]
J Kemper et al. Rofo. 2006 Nov.

Abstract

The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of "Multislice CT Urography (MSCTU)" has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of pelvicalyceal and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources