Safety factor in single human motor end-plates studied in vivo with single fibre electromyography
- PMID: 171345
- PMCID: PMC492075
- DOI: 10.1136/jnnp.38.8.799
Safety factor in single human motor end-plates studied in vivo with single fibre electromyography
Abstract
In a single fibre EMG investigation on healthy subjects the relationship between the neuromuscular jitter and the safety factor of the motor end-plate relative to curare was studied. A positive correlation was found between the jitter increase after a standard dose of D-tubocurarine and the initial jitter. The conclusion was drawn that the neuromuscular jitter can be used as an indicator of the safety factor. There are a number of nerve-muscle disorders in which the jitter is increased, probably indicating a reduced safety factor which may be of clinical importance when these patients are subjected to diseases or drugs which would otherwise not produce neuromuscular symptomatology.
Similar articles
-
Regional curare for the reduction of the safety factor in human motor end-plates studied with single fibre electromyography.J Neurol Neurosurg Psychiatry. 1975 Aug;38(8):805-9. doi: 10.1136/jnnp.38.8.805. J Neurol Neurosurg Psychiatry. 1975. PMID: 171346 Free PMC article.
-
Characterization of the relationship between motor end-plate jitter and the safety factor.Muscle Nerve. 1998 May;21(5):628-36. doi: 10.1002/(sici)1097-4598(199805)21:5<628::aid-mus9>3.0.co;2-a. Muscle Nerve. 1998. PMID: 9572242
-
Axonal stimulation for end-plate jitter studies.J Neurol Neurosurg Psychiatry. 1986 Jun;49(6):677-85. doi: 10.1136/jnnp.49.6.677. J Neurol Neurosurg Psychiatry. 1986. PMID: 3016197 Free PMC article.
-
[Seasonal changes in neuromuscular transmission in experiments on dissected or curarized frog muscles].Neirofiziologiia. 1990;22(6):745-51. Neirofiziologiia. 1990. PMID: 1965851 Russian.
-
The study of normal and abnormal neuromuscular transmission with single fibre electromyography.J Neurosci Methods. 1997 Jun 27;74(2):145-54. doi: 10.1016/s0165-0270(97)02245-0. J Neurosci Methods. 1997. PMID: 9219884 Review.
Cited by
-
Jitter in the muscle fibre.J Neurol Neurosurg Psychiatry. 1990 Jan;53(1):49-54. doi: 10.1136/jnnp.53.1.49. J Neurol Neurosurg Psychiatry. 1990. PMID: 2154556 Free PMC article.
-
Regional curare for the reduction of the safety factor in human motor end-plates studied with single fibre electromyography.J Neurol Neurosurg Psychiatry. 1975 Aug;38(8):805-9. doi: 10.1136/jnnp.38.8.805. J Neurol Neurosurg Psychiatry. 1975. PMID: 171346 Free PMC article.
-
Subclinical diabetic polyneuropathy: early detection of involvement of different nerve fibre types.J Neurol Neurosurg Psychiatry. 1993 May;56(5):509-14. doi: 10.1136/jnnp.56.5.509. J Neurol Neurosurg Psychiatry. 1993. PMID: 8389397 Free PMC article.
-
Single fiber electromyography. A method for the evaluation of motor axonopathy during toxicity studies in dogs.Agents Actions. 1981 Nov;11(5):510-4. doi: 10.1007/BF02004714. Agents Actions. 1981. PMID: 7337073
-
The regional curare test in myasthenia gravis.J Neurol. 1977 Mar 21;214(4):257-65. doi: 10.1007/BF00316571. J Neurol. 1977. PMID: 67189
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources