Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Winter;31(4):283-91.
doi: 10.1016/j.meddos.2006.05.003.

Inverse-planned, dynamic, multi-beam, intensity-modulated radiation therapy (IMRT): a promising technique when target volume is the left breast and internal mammary lymph nodes

Affiliations

Inverse-planned, dynamic, multi-beam, intensity-modulated radiation therapy (IMRT): a promising technique when target volume is the left breast and internal mammary lymph nodes

Carmen C Popescu et al. Med Dosim. 2006 Winter.

Abstract

The purpose of this study was to determine the optimum beam number and orientation for inverse-planned, dynamic intensity-modulated radiation therapy (IMRT) for treatment of left-sided breast cancer and internal mammary nodes (IMNs) to improve target coverage while reducing cardiac and ipsilateral lung irradiation. Computed tomography (CT) data was used from 5 patients with left-sided breast cancer in whom the heart was close to the chest wall. The planning target volume (PTV) was the full breast plus ipsilateral IMNs. Two geometric beam arrangements were investigated, 240 degrees and 190 degrees sector angles, and the number of beams was increased from 7 to 9 to 11. Dose comparison metrics included: PTV homogeneity and conformity indices (HI, CI), heart V30, left lung V20, and mean doses to surrounding structures. To assess clinical application, the IMRT plans with 11 beams equally spaced in a 190 degrees sector angle were compared to conventional plans. Treatment times were modeled. The 190 degrees IMRT plans improved PTV HI and CI and reduced mean dose to the heart, lungs, contralateral breast, and total healthy tissue (all p < 0.05) compared to a 240 degrees sector angle. The 11-beam plan significantly improved PTV HI and CI, heart V30, left lung V20, and healthy tissue V5 compared to a 7-beam plan (all p < 0.05). The 11-beam plan reduced heart V30 and left lung V20 (p < 0.05) without compromising PTV coverage, compared to a 9-beam plan. Compared to a conventional plan, the IMRT class solution significantly improved PTV HI and CI (both p < 0.01), heart V30 (p = 0.01), and marginally reduced left lung V20 (p = 0.07) but increased contralateral breast and lung mean dose (p < 0.001) and healthy tissue V5 (p < 0.001). An 11-beam 190 degrees sector angle IMRT technique as a class solution is clinically feasible.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources