Diagnostic value of 18F-FDG PET/CT in trauma patients with suspected chronic osteomyelitis
- PMID: 17136411
- DOI: 10.1007/s00259-006-0290-4
Diagnostic value of 18F-FDG PET/CT in trauma patients with suspected chronic osteomyelitis
Abstract
Purpose: To retrospectively evaluate the diagnostic value of (18)F-FDG PET/CT in trauma patients with suspected chronic osteomyelitis.
Methods: Thirty-three partial body (18)F-FDG PET/CT scans were performed in 33 patients with trauma suspected of having chronic osteomyelitis. In 10 and 23 patients, infection was suspected in the axial and appendicular skeleton, respectively. In 18 patients, PET/CT was performed in the presence of metallic implants. Histopathology or bacteriological culture was used as the standard of reference. For statistical analysis, sensitivity, specificity and accuracy were calculated in relation to findings of the reference standard.
Results: Of 33 PET/CT scans, 17 were true positive, 13 true negative, two false positive and one false negative. Eighteen patients had chronic osteomyelitis and 15 had no osseous infection according to the reference standard. Sensitivity, specificity and accuracy for (18)F-FDG PET/CT was 94%, 87% and 91% for the whole group, 88%, 100% and 90% for the axial skeleton and 100%, 85% and 91% for the appendicular skeleton, respectively.
Conclusion: (18)F-FDG PET/CT is a highly sensitive and specific method for the evaluation of chronic infection in the axial and appendicular skeleton in patients with trauma. PET/CT allows precise anatomical localisation and characterisation of the infectious focus and demonstrates the extent of chronic osteomyelitis with a high degree of accuracy.
Similar articles
-
The diagnostic value of [(18)F]FDG PET for the detection of chronic osteomyelitis and implant-associated infection.Eur J Nucl Med Mol Imaging. 2016 Apr;43(4):749-61. doi: 10.1007/s00259-015-3221-4. Epub 2015 Nov 7. Eur J Nucl Med Mol Imaging. 2016. PMID: 26547722
-
Chronic osteomyelitis: detection with FDG PET and correlation with histopathologic findings.Radiology. 1998 Mar;206(3):749-54. doi: 10.1148/radiology.206.3.9494496. Radiology. 1998. PMID: 9494496
-
The value of 18-FDG PET/CT in the diagnosis and management of implant-related infections of the tibia: a case series.Injury. 2015 Jul;46(7):1377-82. doi: 10.1016/j.injury.2015.03.002. Epub 2015 Mar 10. Injury. 2015. PMID: 25801065
-
Usefulness of F-18-fluorodeoxyglucose positron emission tomography to confirm suspected pancreatic cancer: a meta-analysis.Eur J Surg Oncol. 2014 Jul;40(7):794-804. doi: 10.1016/j.ejso.2014.03.016. Epub 2014 Apr 3. Eur J Surg Oncol. 2014. PMID: 24755095 Review.
-
PET/CT in musculoskeletal infection.Semin Musculoskelet Radiol. 2007 Dec;11(4):353-64. doi: 10.1055/s-2008-1060337. Semin Musculoskelet Radiol. 2007. PMID: 18324599 Review.
Cited by
-
Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET/CT) Findings in an Unusual Case of Multiple Myeloma Presenting with a Large Extra-Axial Intracranial Mass.Pol J Radiol. 2016 Dec 16;81:602-605. doi: 10.12659/PJR.899444. eCollection 2016. Pol J Radiol. 2016. PMID: 28058074 Free PMC article.
-
Diagnostic performance of 18F-FDG PET/CT in patients with spinal infection: a systematic review and a bivariate meta-analysis.Eur J Nucl Med Mol Imaging. 2020 May;47(5):1287-1301. doi: 10.1007/s00259-019-04571-6. Epub 2019 Nov 15. Eur J Nucl Med Mol Imaging. 2020. PMID: 31729539
-
[18F]FDG PET accurately differentiates infected and non-infected non-unions after fracture fixation.Eur J Nucl Med Mol Imaging. 2017 Mar;44(3):432-440. doi: 10.1007/s00259-016-3528-9. Epub 2016 Oct 5. Eur J Nucl Med Mol Imaging. 2017. PMID: 27704194 Free PMC article.
-
Application of Nuclear Medicine Techniques in Musculoskeletal Infection: Current Trends and Future Prospects.J Clin Med. 2024 Feb 13;13(4):1058. doi: 10.3390/jcm13041058. J Clin Med. 2024. PMID: 38398371 Free PMC article. Review.
-
Diagnosing Fracture-Related Infection: Current Concepts and Recommendations.J Orthop Trauma. 2020 Jan;34(1):8-17. doi: 10.1097/BOT.0000000000001614. J Orthop Trauma. 2020. PMID: 31855973 Free PMC article.