Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye
- PMID: 17137989
- DOI: 10.1016/j.jcrs.2006.08.030
Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye
Abstract
Purpose: To assess whether the retrospectively calculated intraocular lens (IOL) position value in the first eye reduces the error of predicted refraction in the second.
Setting: Prince of Wales Hospital, Sydney, Australia.
Methods: One hundred twenty-one consecutive patients who had bilateral cataract surgery with the same IOL (SI-30NB, Advanced Medical Optics) were identified. The case-derived A-constant in the first eye was calculated from the postoperative refraction. This value was used to calculate the adjusted error of predicted refraction in the second eye and compared against the unadjusted error in that eye (calculated using manufacturer's A-constant).
Results: Axial length (r = 0.97), corneal power (r = 0.97), and IOL power (r = 0.90) were strongly correlated between eyes with no statistically significant mean interocular difference. Although there was no significant interocular difference in the mean error of predicted refraction (SRK/T), there was only a moderate correlation between eyes (r = 0.40). Using the axial length vergence formula, the mean adjusted error of predicted refraction in the second eye (-0.66 diopter [D]) was significantly larger than the mean unadjusted error (-0.47 D) (P = .029). The standard deviation of the adjusted error of predicted refraction (SRK/T) in the second eye (0.85 D) was greater than the standard deviation of the unadjusted error (0.79). Similarly, the adjusted mean absolute error of predicted refraction (0.65 D) was greater than the unadjusted error (0.63 D).
Conclusion: Adjusting the IOL power in the second eye by the amount of overprediction or underprediction in the first eye did not improve prediction accuracy because the error of predicted refraction varied independently between the 2 eyes of an individual.
Similar articles
-
Intraocular lens power selection in the second eye of patients undergoing bilateral, sequential cataract extraction.Ophthalmology. 2010 Jan;117(1):49-54. doi: 10.1016/j.ophtha.2009.06.020. Epub 2009 Oct 7. Ophthalmology. 2010. PMID: 19815281
-
Use of fellow eye data in the calculation of intraocular lens power for the second eye.Ophthalmology. 2011 Sep;118(9):1710-5. doi: 10.1016/j.ophtha.2011.04.030. Epub 2011 Jul 2. Ophthalmology. 2011. PMID: 21723613
-
Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons Post-Keratorefractive Intraocular Lens Power Calculator.J Cataract Refract Surg. 2010 Sep;36(9):1466-73. doi: 10.1016/j.jcrs.2010.03.044. J Cataract Refract Surg. 2010. PMID: 20692556
-
Intraocular lens power calculation in eyes with keratoconus.J Cataract Refract Surg. 2020 May;46(5):778-783. doi: 10.1097/j.jcrs.0000000000000082. J Cataract Refract Surg. 2020. PMID: 32358275 Review.
-
Intraocular lens power calculation in children.Surv Ophthalmol. 2007 Sep-Oct;52(5):474-82. doi: 10.1016/j.survophthal.2007.06.010. Surv Ophthalmol. 2007. PMID: 17719370 Review.
Cited by
-
Bilateral Same-Day Cataract Surgery: An Idea Whose Time Has Come #COVID-19.Ophthalmology. 2021 Jan;128(1):13-14. doi: 10.1016/j.ophtha.2020.08.028. Epub 2020 Sep 2. Ophthalmology. 2021. PMID: 32888947 Free PMC article. No abstract available.
-
Interocular biometric parameters comparison measured with swept-source technology.Int Ophthalmol. 2022 Jan;42(1):239-251. doi: 10.1007/s10792-021-02020-8. Epub 2021 Aug 21. Int Ophthalmol. 2022. PMID: 34417946 Free PMC article.
-
Using the First-Eye Back-Calculated Effective Lens Position to Improve Refractive Outcome of the Second Eye.J Clin Med. 2022 Dec 26;12(1):184. doi: 10.3390/jcm12010184. J Clin Med. 2022. PMID: 36614985 Free PMC article.
-
Refractive outcomes and safety profile after sequential bilateral cataract surgery.Int Ophthalmol. 2025 Mar 31;45(1):129. doi: 10.1007/s10792-025-03472-y. Int Ophthalmol. 2025. PMID: 40163199
-
The binocular intraocular lens power difference in eyes with different axial lengths.Int J Ophthalmol. 2022 Jun 18;15(6):924-931. doi: 10.18240/ijo.2022.06.09. eCollection 2022. Int J Ophthalmol. 2022. PMID: 35814895 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials