Static versus dynamic loading in the mechanical modulation of vertebral growth
- PMID: 17139211
- DOI: 10.1097/01.brs.0000248810.77151.22
Static versus dynamic loading in the mechanical modulation of vertebral growth
Abstract
Study design: Measures of absolute and relative growth modulation were used to determine the effects of static and dynamic asymmetric loading of vertebrae in the rat tail.
Objectives: To quantify the differences between static and dynamic asymmetric loading in vertebral bone growth modulation.
Summary of background data: The creation and correction of vertebral wedge deformities have been previously described in a rat-tail model using static loading. The effects of dynamic loading on growth modulation in the spine have not been characterized.
Methods: A total of 36 immature Sprague-Dawley rats were divided among four different groups: static loading (n = 12, 0.0 Hz), dynamic loading (n = 12, 1.0 Hz), sham operated (n = 6), and growth controls (n = 6). An external fixator was placed across the sixth and eighth caudal vertebrae as the unviolated seventh caudal vertebra was evaluated for growth modulation. Static or dynamic asymmetric loads were applied at a loading magnitude of 55% body weight. After 3 weeks of loading, growth modulation was assessed using radiographic measurements of vertebral wedge angles and vertebral body heights.
Results: The dynamically loaded rats had a final average wedge deformity of 15.2+/- 6.4 degrees, which was significantly greater than the statically loaded rats whose final deformity averaged 10.3 degrees +/- 3.7 degrees (P < 0.03). The deformity in both groups was statistically greater than the sham-operated (1.1+/- 2.0 degrees) and growth control rats (0.0+/- 1.0 degrees) (P < 0.001). The longitudinal growth was significantly lower on the concavity compared with the convexity in both the dynamically (0.34 +/- 0.23 mm vs. 0.86 +/- 0.23 mm) and statically (0.46 +/- 0.19 mm vs. 0.83 +/- 0.32 mm) loaded rats (P < 0.001). These growth rates were significantly less than the sham operated and growth control rats (P < 0.001).
Conclusions: A variety of fusionless scoliosis implant strategies have been proposed that use both rigid and flexible implants to modulate vertebral bone growth. The results from this study demonstrate that dynamic loading of the vertebrae provides the greatest growth modulation potential.
Similar articles
-
Mechanical modulation of growth for the correction of vertebral wedge deformities.J Orthop Res. 1999 Jul;17(4):518-24. doi: 10.1002/jor.1100170409. J Orthop Res. 1999. PMID: 10459757
-
In vivo dynamic bone growth modulation is less detrimental but as effective as static growth modulation.Bone. 2011 Nov;49(5):996-1004. doi: 10.1016/j.bone.2011.07.008. Epub 2011 Jul 19. Bone. 2011. PMID: 21784187
-
Growth plate chondrocyte enlargement modulated by mechanical loading.Stud Health Technol Inform. 2002;88:378-81. Stud Health Technol Inform. 2002. PMID: 15456065
-
Mechanical modulation of spinal growth and progression of adolescent scoliosis.Stud Health Technol Inform. 2008;135:75-83. Stud Health Technol Inform. 2008. PMID: 18401082 Review.
-
Diaphyseal bone growth and adaptation: models and data.Stud Health Technol Inform. 1997;40:17-23. Stud Health Technol Inform. 1997. PMID: 10168877 Review.
Cited by
-
Short term outcomes and complications of distal ulnar ostectomy in 23 juvenile dogs with carpal valgus secondary to discordant radial-ulnar physeal growth.Front Vet Sci. 2022 Sep 9;9:971527. doi: 10.3389/fvets.2022.971527. eCollection 2022. Front Vet Sci. 2022. PMID: 36157189 Free PMC article.
-
A novel fusionless vertebral physeal device inducing spinal growth modulation for the correction of spinal deformities.Eur Spine J. 2008 Oct;17(10):1329-35. doi: 10.1007/s00586-008-0723-9. Epub 2008 Aug 19. Eur Spine J. 2008. PMID: 18712419 Free PMC article.
-
Growth modulation in the management of growing spine deformities.J Child Orthop. 2009 Feb;3(1):1-9. doi: 10.1007/s11832-008-0145-6. Epub 2008 Nov 20. J Child Orthop. 2009. PMID: 19308606 Free PMC article.
-
Mechanical stimulation of growth plate chondrocytes: Previous approaches and future directions.Exp Mech. 2019 Nov;59(9):1261-1274. doi: 10.1007/s11340-018-0424-1. Epub 2018 Aug 17. Exp Mech. 2019. PMID: 31787777 Free PMC article.
-
Potential regenerative rehabilitation technology: implications of mechanical stimuli to tissue health.BMC Res Notes. 2014 Jun 3;7:334. doi: 10.1186/1756-0500-7-334. BMC Res Notes. 2014. PMID: 24894666 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials