The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device
- PMID: 17145418
- DOI: 10.1016/j.jvs.2006.08.028
The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device
Abstract
Objective: Endovascular repair of abdominal aortic aneurysm (AAA) is complicated by the potential for stent graft migration over time. Factors including the type of fixation, initial proximal fixation length, and dilation and elongation of the infrarenal aortic neck may contribute to device migration. We sought to determine when device migration is a real phenomenon with actual device movement that compromises aneurysm exclusion.
Methods: Computed tomographic (CT) scans and computer reconstructions of all patients undergoing endovascular AAA repair with a passive fixation device at our institution from June 1996 to October 2004 were retrospectively reviewed. The distance from the distal renal artery to the proximal end of the stent graft at the time of initial deployment was determined for each patient. Migration was defined as a distance increase greater than 5 mm in the follow-up period; proximal fixation length, aortic neck enlargement and elongation, and neck angle were then measured. Data were further analyzed with respect to AAA growth, development of endoleak, AAA rupture, and the need for reintervention.
Results: A total of 308 patients with endovascular AAA repairs using a passive fixation device had complete postoperative imaging data sets; 48 patients (15.6%) with stent graft migration of 5 mm or more were identified, and 25 (8.1%) of these had a migration of 10 mm or more. Seventeen (35.4%) of 48 migration patients had a total loss of the proximal seal zone (loss patients); their average migration distance was 17.7 +/- 12.0 mm, with a mean neck shortening of 13.6 +/- 14.2 mm, and the average proximal fixation length loss was 14.0 +/- 7.6 mm. Those 31 patients with an intact proximal seal zone (nonloss patients) showed an average migration of 9.4 +/- 3.7 mm, with a mean neck lengthening of 9.6 +/- 8.4 mm and an average proximal fixation length change of 0.7 +/- 8.0 mm. Univariate analysis demonstrated significant differences between the loss and nonloss patients in follow-up duration (65.9 +/- 20.4 months vs 45.9 +/- 26.4 months; P = .01), neck dilatation at the distal renal artery (4.6 +/- 4.5 mm vs 1.8 +/- 1.9 mm; P = .026), stent graft migration distance (17.7 +/- 12.0 mm vs 9.4 +/- 3.7 mm; P = .001), change in aortic neck length (-13.6 +/- 14.2 mm vs 9.6 +/- 8.4 mm; P < .0001), change in proximal fixation length (-14.0 +/- 7.6 mm vs 0.7 +/- 8.0 mm; P < .0001), change in AAA size (1.8 +/- 7.1 mm vs -3.6 +/- 9.7 mm; P = .033), and use of a stiff body stent graft (47.1% vs 19.4%; P = .043). However, only change in aortic neck length was statistically significant on multivariate analysis (odds ratio, 0.75; 95% confidence interval, 0.591-0.961; P = .022). There were no differences between the loss and nonloss patients in time to migration discovery, initial AAA size, initial aortic neck diameter or length, initial device oversizing, initial neck angle, neck angle increase, type II endoleak, or AAA rupture. Eight of the 17 loss patients have been treated with proximal aortic cuffs; the remainder have refused reintervention, died of unrelated causes, or elected to have open repair.
Conclusions: Postoperative elongation of the infrarenal aortic neck may create the radiographic perception of migration without necessarily causing a loss of proximal stent graft fixation. Patients with a total loss of the proximal seal zone actually have infrarenal aortic neck shortening, with a degree of neck dilatation beyond initial device oversizing that may compromise proximal fixation length. Conversely, those with an intact proximal seal zone demonstrate aortic neck elongation equivalent to migration, with no loss of proximal fixation length; these patients have a benign natural history without intervention. Thus, aortic neck dilatation beyond oversizing, aortic neck shortening, and loss of proximal fixation length are more clinically relevant predictors of proximal stent graft failure than simple migration distance.
Similar articles
-
Long-term outcomes of Palmaz stent placement for intraoperative type Ia endoleak during endovascular aneurysm repair.Ann Vasc Surg. 2011 Jan;25(1):120-6. doi: 10.1016/j.avsg.2010.08.004. Ann Vasc Surg. 2011. PMID: 21172587
-
Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts.J Vasc Surg. 2007 Feb;45(2):250-7. doi: 10.1016/j.jvs.2006.09.061. J Vasc Surg. 2007. PMID: 17263997
-
Stent graft migration after endovascular aneurysm repair: importance of proximal fixation.J Vasc Surg. 2003 Dec;38(6):1264-72; discussion 1272. doi: 10.1016/s0741-5214(03)00946-7. J Vasc Surg. 2003. PMID: 14681625 Clinical Trial.
-
Aorfix™ device for abdominal aortic aneurysm with challenging anatomy.J Cardiovasc Surg (Torino). 2014 Feb;55(1):61-70. J Cardiovasc Surg (Torino). 2014. PMID: 24356047 Review.
-
The AneuRx stent graft: four-year results and worldwide experience 2000.J Vasc Surg. 2001 Feb;33(2 Suppl):S135-45. doi: 10.1067/mva.2001.111676. J Vasc Surg. 2001. PMID: 11174825 Review.
Cited by
-
Changes in the Normal Infrarenal Aortic Length and Tortuosity in Elderly People.Vasc Specialist Int. 2020 Mar 31;36(1):15-20. doi: 10.5758/vsi.2020.36.1.15. Vasc Specialist Int. 2020. PMID: 32292764 Free PMC article.
-
The Long-Term Progression of Aneurysmal Disease in Common Iliac Arteries After Standard EVAR and Its Clinical Implications.Int J Vasc Med. 2024 Nov 29;2024:4229582. doi: 10.1155/ijvm/4229582. eCollection 2024. Int J Vasc Med. 2024. PMID: 39650203 Free PMC article.
-
Changes in suprarenal and infrarenal aortic angles after endovascular aneurysm repair.Ann Surg Treat Res. 2014 Oct;87(4):197-202. doi: 10.4174/astr.2014.87.4.197. Epub 2014 Sep 25. Ann Surg Treat Res. 2014. PMID: 25317415 Free PMC article.
-
Less Aortic Neck Dilatation of the ALTO Stent Graft compared to the Self-Expanding Stent Grafts after Endovascular Aortic Repair for Abdominal Aortic Aneurysms.Cardiovasc Intervent Radiol. 2025 Apr;48(4):438-446. doi: 10.1007/s00270-025-03996-x. Epub 2025 Mar 17. Cardiovasc Intervent Radiol. 2025. PMID: 40097624
-
Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair.J Endovasc Ther. 2019 Dec;26(6):855-864. doi: 10.1177/1526602819882379. J Endovasc Ther. 2019. PMID: 31736427 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical