Artifacts and pitfalls in myocardial perfusion imaging
- PMID: 17146108
Artifacts and pitfalls in myocardial perfusion imaging
Abstract
Myocardial perfusion imaging (MPI) is an important imaging modality in the management of patients with cardiovascular disease. MPI plays a key role in diagnosing cardiovascular disease, establishing prognosis, assessing the effectiveness of therapy, and evaluating viability. However, MPI is a complex process, subject to a variety of artifacts and pitfalls, which may limit its clinical utility. These factors may be related to the patient (including unique aspects of the patient's heart), the nuclear medicine equipment, or the actions of the technologist. After reviewing this article, the reader should be familiar with the causes and the effects of these potential artifacts and pitfalls. The reader should develop an understanding of steps to limit these factors, actions to correct them if they do arise and, when necessary, how to incorporate their influence into the interpretation of the study.
Similar articles
-
Adenosine stress protocols for myocardial perfusion imaging.J Nucl Cardiol. 2007 May-Jun;14(3):415-6. doi: 10.1016/j.nuclcard.2007.04.005. J Nucl Cardiol. 2007. PMID: 17556176 Review. No abstract available.
-
Image reconstruction using filtered backprojection and iterative method: effect on motion artifacts in myocardial perfusion SPECT.J Nucl Med Technol. 2006 Dec;34(4):220-3. J Nucl Med Technol. 2006. PMID: 17146110
-
Optimal SPECT processing and display: making bad studies look good to get the right answer.J Nucl Cardiol. 2006 Nov;13(6):855-66. doi: 10.1016/j.nuclcard.2006.10.014. J Nucl Cardiol. 2006. PMID: 17174816 Review. No abstract available.
-
Review of the linogram and sinogram: an easy way to detect off-peak artifacts in myocardial perfusion SPECT.J Nucl Med Technol. 2009 Sep;37(3):188-90. doi: 10.2967/jnmt.108.061218. Epub 2009 Aug 19. J Nucl Med Technol. 2009. PMID: 19692451 Review.
-
Procedure guidelines for radionuclide myocardial perfusion imaging.Nucl Med Commun. 2003 Oct;24(10):1105-19. doi: 10.1097/01.mnm.0000095842.16659.4d. Nucl Med Commun. 2003. PMID: 14508167
Cited by
-
Cost-effectiveness of cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary artery disease in Germany.J Cardiovasc Magn Reson. 2013 Apr 10;15(1):30. doi: 10.1186/1532-429X-15-30. J Cardiovasc Magn Reson. 2013. PMID: 23574690 Free PMC article.
-
Respiratory motion resulting in a pseudo-ischemia pattern on stress PET-CT imaging.J Nucl Cardiol. 2016 Feb;23(1):159-60. doi: 10.1007/s12350-015-0195-3. Epub 2015 Jun 12. J Nucl Cardiol. 2016. PMID: 26068975 No abstract available.
-
Interaction between the effects of proton pump inhibitors and aspirin on gastric wall sestamibi uptake on myocardial perfusion imaging.J Nucl Cardiol. 2021 Oct;28(5):1976-1985. doi: 10.1007/s12350-019-01951-1. Epub 2019 Nov 18. J Nucl Cardiol. 2021. PMID: 31741323
-
Motion correction and myocardial perfusion SPECT using manufacturer provided software. Does it affect image interpretation?Eur J Nucl Med Mol Imaging. 2010 Apr;37(4):758-64. doi: 10.1007/s00259-009-1290-y. Epub 2009 Nov 14. Eur J Nucl Med Mol Imaging. 2010. PMID: 19915841
-
Optimizing bioimpedance measurement configuration for dual-gated nuclear medicine imaging: a sensitivity study.Med Biol Eng Comput. 2011 Jul;49(7):783-91. doi: 10.1007/s11517-011-0787-2. Epub 2011 May 27. Med Biol Eng Comput. 2011. PMID: 21618055
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources