Development of a solid-phase microextraction method with micellar desorption for the determination of chlorophenols in water samples. Comparison with conventional solid-phase microextraction method
- PMID: 17150227
- DOI: 10.1016/j.chroma.2006.11.050
Development of a solid-phase microextraction method with micellar desorption for the determination of chlorophenols in water samples. Comparison with conventional solid-phase microextraction method
Abstract
A novel analytical method is presented for the determination of chlorophenols in water. This method involves pre-concentration by solid-phase microextraction (SPME) and an external desorption using a micellar medium as desorbing agent. Final analysis of the selected chlorophenols compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detection (DAD). Optimum conditions for desorption, using the non-ionic surfactant polyoxyethylene 10 lauryl ether (POLE), such as surfactant concentration and time were studied. A satisfactory reproducibility for the extraction of target compounds, between 6 and 15%, was obtained, and detection limits were in the range of 1.1-5.9ngmL(-1). The developed method is evaluated and compared with the conventional one using organic solvent as a desorbing agent. The method was successfully applied to the determination of chlorophenols in water samples from different origin. This study has demonstrated that solid-phase microextraction with micellar desorption (SPME-MD) can be used as an alternative to conventional SPME method for the extraction of chlorophenols in water samples.
Similar articles
-
Coupling of solid-phase microextraction with micellar desorption and high performance liquid chromatography for the determination of pharmaceutical residues in environmental liquid samples.Biomed Chromatogr. 2009 Nov;23(11):1175-85. doi: 10.1002/bmc.1240. Biomed Chromatogr. 2009. PMID: 19444801
-
Microwave-assisted micellar extraction coupled with solid-phase extraction for preconcentration of pharmaceuticals in molluscs prior to determination by HPLC.Biomed Chromatogr. 2008 Oct;22(10):1115-22. doi: 10.1002/bmc.1033. Biomed Chromatogr. 2008. PMID: 18506739
-
Application of liquid-liquid-liquid microextraction and ion-pair liquid chromatography coupled with photodiode array detection for the determination of chlorophenols in water.J Chromatogr A. 2008 Jun 6;1193(1-2):79-84. doi: 10.1016/j.chroma.2008.03.082. Epub 2008 Apr 8. J Chromatogr A. 2008. PMID: 18420216
-
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples.Talanta. 2012 Jan 30;89:1-11. doi: 10.1016/j.talanta.2011.12.044. Epub 2011 Dec 22. Talanta. 2012. PMID: 22284452 Review.
-
In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters.J Chromatogr A. 2010 Apr 16;1217(16):2695-702. doi: 10.1016/j.chroma.2010.01.018. Epub 2010 Jan 14. J Chromatogr A. 2010. PMID: 20102766 Review.
Cited by
-
Methodologies for the extraction of phenolic compounds from environmental samples: new approaches.Molecules. 2009 Jan 9;14(1):298-320. doi: 10.3390/molecules14010298. Molecules. 2009. PMID: 19136918 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources