Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Jan;98(1):110-5.
doi: 10.1093/bja/ael327.

Analgesia with sevoflurane during labour: ii. Sevoflurane compared with Entonox for labour analgesia

Affiliations
Free article
Randomized Controlled Trial

Analgesia with sevoflurane during labour: ii. Sevoflurane compared with Entonox for labour analgesia

S T Yeo et al. Br J Anaesth. 2007 Jan.
Free article

Abstract

Background: We determined the optimal inspired sevoflurane concentration for use during labour as 0.8% in our previous study. This study compared sevoflurane at a concentration of 0.8% and Entonox((R)) (nitrous oxide 50%: oxygen 50%) for analgesia during labour in 32 healthy parturients.

Methods: Each mother underwent two open-label, three-part sequences in random order, Entonox-sevoflurane-Entonox or sevoflurane-Entonox-sevoflurane. In each part the agent was self-administered during 10 contractions. A 100 mm visual analogue scores for pain relief and sedation was completed immediately after each contraction.

Results: Two patients withdrew during administration of sevoflurane (because of its odour) and five during Entonox (requesting epidural analgesia). Of the remaining women, data were available for analysis from 29 participants: median (IQR [range]) pain relief scores were significantly higher for sevoflurane 67 (55-74 [33-100]) mm than for Entonox 51 (40-69.5 [13-100]) mm (P<0.037). Nausea and vomiting were more common in the Entonox group [relative risk 2.7 (95% CI 1.3-5.7); P=0.004]. No other adverse effects were observed in the mothers or babies. There was significantly more sedation with sevoflurane than with Entonox {74 (66.5-81 [32.5-100]) and 51 (41-69.5 [13-100]) mm, respectively; P<0.001}. Twenty-nine patients preferred sevoflurane to Entonox and found its sedative effects helpful.

Conclusions: We conclude that self-administered sevoflurane at subanaesthetic concentration (0.8%) can provide useful pain relief during the first stage of labour, and to a greater extent than Entonox. Although greater sedative effects were experienced with sevoflurane, it was preferred to Entonox.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources