Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Dec;19(12):1206-12.
doi: 10.1016/j.amjhyper.2006.05.010.

Evaluation of a new carotid intima-media thickness measurement by B-mode ultrasonography using an innovative measurement software, intimascope

Affiliations
Comparative Study

Evaluation of a new carotid intima-media thickness measurement by B-mode ultrasonography using an innovative measurement software, intimascope

Toshihiko Yanase et al. Am J Hypertens. 2006 Dec.

Abstract

Carotid intima-media thickness (IMT), an indicator of atherosclerosis and coronary heart disease (CHD) is usually evaluated by eye measurement under B-scope carotid artery ultrasonography. However, the axial resolution of this system is >/=0.1 mm, which causes difficulties in respect to accuracy and reproducibility. We evaluated a newly developed B-scope carotid artery ultrasonography programmed by an innovative measurement software, Intimascope (Media Cross Co. Ltd., Tokyo, Japan), which measures IMT with 10 times higher axial resolution at an estimated scale of 0.01 mm. Intraobserver or interobserver coefficient of variation (CV) of the computer-based average IMT (aver-IMT) value and 3-point IMT value were much smaller than the corresponding value by conventional eye-measurement method (3-point value). We measured IMT of 427 asymptomatic subjects undergoing medical checkups (243 men and 184 women, 23 to 73 years of age). Although the mean values of aver-IMT and 3-point IMT of 427 subjects were comparable with that of the eye measurement method, the aver-IMT showed the smallest SD (standard deviation) and CV values. In both men and women, multivariate regression analysis revealed significant contributions of age and LDL-C to the aver-IMT value. Univariate regression analysis revealed that the aver-IMT value of total subjects showed the highest correlation coefficient values with most risk factors and risk assessment score, Framingham Risk Assessment, or Prospective Cardiovascular Munster study (PROCAM) Risk Score. These results may suggest superiority of computer-based aver-IMT over 3-point IMT by either computer-based or eye measurement method. Carotid aver-IMT measurement using the new Intimascope software may provide a more precise and reproducible index of atherosclerosis than does conventional IMT measurement.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms