Discolouration in potable water distribution systems: a review
- PMID: 17174377
- DOI: 10.1016/j.watres.2006.09.028
Discolouration in potable water distribution systems: a review
Abstract
A large proportion of the customer contacts that drinking water supply companies receive stem from the occurrence of discoloured water. Currently, such complaints are dealt with in a reactive manner. However, water companies are being driven to implement planned activities to control discolouration prior to contacts occurring. Hence improved understanding of the dominant processes and predictive and management tools are needed. The material responsible for discolouration has a variety of origins and a range of processes and mechanisms may be associated with its accumulation within distribution systems. Irrespective of material origins, accumulation processes and mechanisms, discolouration events occur as a result of systems changes leading to mobilisation of the accumulations from within the network. Despite this conceptual understanding, there are very few published practicable tools and techniques available to aid water companies in the planned management and control of discolouration problems. Two recently developed and published, but different approaches to address this are reviewed here: the PODDS model which was developed to predict levels of turbidity as a result of change in hydraulic conditions, but which is semi-empirical and requires calibration; and the resuspension potential method which was developed to directly measure discolouration resulting from a controlled change in hydraulic conditions, providing a direct assessment of discolouration risk, although intrinsically requiring the limited generation of discoloured water within a live network. Both these methods support decision making on the need for maintenance operations. While risk evaluation and implementation of appropriate maintenance can be implemented to control discolouration risk, new material will continue to accumulate and hence an ongoing programme of maintenance is required. One sustainable measure to prevent such re-accumulation of material is the adoption of a self-cleaning threshold, an hydraulic force which a pipe experiences on a regular basis that effectively prevents the accumulation of material. This concept has been effectively employed for the design of new networks in the Netherlands. Alternatively, measures could be implemented to limit or prevent particles from entering or being generated within the network, such as by improving treatment or preventing the formation of corrosion by-products through lining or replacing ferrous pipes. The cost benefit of such capex investment or ongoing opex is uncertain as the quantification and relative significance of factors possibly leading to material accumulation are poorly understood. Hence, this is an area in need of significant further practical research and development.
Similar articles
-
Asset deterioration and discolouration in water distribution systems.Water Res. 2011 Jan;45(1):113-24. doi: 10.1016/j.watres.2010.08.021. Epub 2010 Aug 17. Water Res. 2011. PMID: 20813391
-
Laboratory studies investigating the processes leading to discolouration in water distribution networks.Water Res. 2008 Oct;42(16):4309-18. doi: 10.1016/j.watres.2008.07.026. Epub 2008 Jul 29. Water Res. 2008. PMID: 18775550
-
Impact of particles on sediment accumulation in a drinking water distribution system.Water Res. 2008 Oct;42(16):4233-42. doi: 10.1016/j.watres.2008.05.024. Epub 2008 Jun 24. Water Res. 2008. PMID: 18789809
-
Integrated treatment and recycling of stormwater: a review of Australian practice.J Environ Manage. 2006 Apr;79(1):102-13. doi: 10.1016/j.jenvman.2005.06.003. Epub 2005 Oct 26. J Environ Manage. 2006. PMID: 16256264 Review.
-
Decentralized systems for potable water and the potential of membrane technology.Water Res. 2009 Feb;43(2):245-65. doi: 10.1016/j.watres.2008.10.030. Epub 2008 Nov 1. Water Res. 2009. PMID: 19010511 Review.
Cited by
-
Evaluation of corrosion control products on a distribution system through crowdsourcing.Environ Sci Pollut Res Int. 2018 Dec;25(34):34487-34495. doi: 10.1007/s11356-018-3361-8. Epub 2018 Oct 11. Environ Sci Pollut Res Int. 2018. PMID: 30311115
-
The interplay of suspended sediment concentration, particle size and fluid velocity on the rapid deposition of suspended iron oxide particles in PVC drinking water pipes.Water Res X. 2022 Apr 15;15:100143. doi: 10.1016/j.wroa.2022.100143. eCollection 2022 May 1. Water Res X. 2022. PMID: 35494337 Free PMC article.
-
Unchartered waters: the unintended impacts of residual chlorine on water quality and biofilms.NPJ Biofilms Microbiomes. 2020 Sep 25;6(1):34. doi: 10.1038/s41522-020-00144-w. NPJ Biofilms Microbiomes. 2020. PMID: 32978404 Free PMC article.
-
Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges.Front Microbiol. 2016 Feb 1;7:45. doi: 10.3389/fmicb.2016.00045. eCollection 2016. Front Microbiol. 2016. PMID: 26870010 Free PMC article. Review.
-
Identifying effects of pipe material, hydraulic condition, and water composition on elemental accumulation in pipe corrosion scales.Environ Sci Pollut Res Int. 2019 Jul;26(19):19906-19914. doi: 10.1007/s11356-019-05401-w. Epub 2019 May 15. Environ Sci Pollut Res Int. 2019. PMID: 31090008
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources