. 2007 Jan 26;1140(1-2):205-12.
doi: 10.1016/j.chroma.2006.11.092. Epub 2006 Dec 18.

Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry

Affiliations

Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry

Fernando Benavente et al. J Chromatogr A. .

Abstract

The use of solid-phase extraction coupled on-line to capillary electrophoresis using electrospray mass spectrometry detection (SPE-CE-ESI-MS) is described for the analysis of peptides in dilute solutions. A SPE microcartridge or analyte concentrator containing C(18) derivatized silica particles as the extraction sorbent was easily constructed near the inlet of the separation capillary using commercially available materials. The reversed-phase sorbent selectively retained the target peptides, enabling large volumes of the sample to be introduced (>100muL). The captured analytes were eluted in a small volume of an appropriate solution (20-50nL). This resulted in sample clean-up and concentration enhancement, with minimum sample handling. As the SPE-CE conditions were compatible with on-line ESI-MS detection, the potential for identifying and characterizing the preconcentrated analytes by SPE-CE-ESI-MS using a sheath-flow CE-ESI-MS interface is also shown. Using separation electrolytes containing N-[carbamoylmethyl]-2-aminoethanesulfonic acid (ACES) at pH 7.4, an elution plug of 80:20 (v/v) (25mM of formic acid in MeCN):H(2)O and a sheath liquid of 20mM of acetic acid in 50:50 (v/v) methanol:H(2)O the concentration limits of detection for the analyzed peptides in the positive ion mode were lowered to nanogram per milliliter levels. The systematic optimization of the operational parameters involved in the development of the SPE-CE method is described in detail, in order to promote robust and quantitative SPE-CE-ESI-MS analysis and facilitate the widespread use of the technique.