Review
. 2007 Mar;41(3):126-33.
doi: 10.1136/bjsm.2006.026344. Epub 2006 Dec 18.

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications

Affiliations
Review

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications

Christopher Byrne et al. Br J Sports Med. 2007 Mar.

Abstract

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Similar articles

Cited by

References

    1. Sawka M N, Wenger C B. Physiological responses to acute exercise‐heat stress. In: Pandolf KB, Sawka MN, Gonzalez RR, eds. Human performance physiology and environmental medicine at terrestrial extremes. Indianapolis IN: Benchmark, 198897–151.
    1. American College of Sports Medicine Position stand. Heat and cold illnesses during distance running. Med Sci Sports Exerc 1996281–10. - PubMed
    1. Ainslie P N, Reilly T. Physiology of accidental hypothermia in the mountains: a forgotten story. Br J Sports Med 200337548–550. - PMC - PubMed
    1. Lim C L, Mackinnon L T. The roles of exercise‐induced immune system disturbances in the pathology of heat stroke. The dual pathway model of heat stroke. Sports Med 20063639–64. - PubMed
    1. Gonzalez‐Alonso J, Teller C, Andersen S L.et al Influence of body temperature on the development of fatigue during prolonged exercise in the heat. J Appl Physiol 1999861032–1039. - PubMed

MeSH terms