The ingestible telemetric body core temperature sensor: a review of validity and exercise applications
- PMID: 17178778
- PMCID: PMC2465229
- DOI: 10.1136/bjsm.2006.026344
The ingestible telemetric body core temperature sensor: a review of validity and exercise applications
Abstract
An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.
Conflict of interest statement
Competing interests: None declared.
Similar articles
-
Monitoring core temperature during exercise: ingestible sensor vs. rectal thermistor.Aviat Space Environ Med. 1993 Aug;64(8):760-3. Aviat Space Environ Med. 1993. PMID: 8368992
-
The validity of temperature-sensitive ingestible capsules for measuring core body temperature in laboratory protocols.Chronobiol Int. 2011 Oct;28(8):719-26. doi: 10.3109/07420528.2011.597530. Epub 2011 Aug 8. Chronobiol Int. 2011. PMID: 21823816
-
Validity and reliability of the myTemp ingestible temperature capsule.J Sci Med Sport. 2018 Mar;21(3):322-326. doi: 10.1016/j.jsams.2017.06.006. Epub 2017 Jun 8. J Sci Med Sport. 2018. PMID: 28645495
-
[Core body temperature monitoring using the telemetric pill].Harefuah. 2003 Mar;142(3):197-202, 238. Harefuah. 2003. PMID: 12696474 Review. Hebrew.
-
Human thermoregulation and measurement of body temperature in exercise and clinical settings.Ann Acad Med Singap. 2008 Apr;37(4):347-53. Ann Acad Med Singap. 2008. PMID: 18461221 Review.
Cited by
-
The effect of skin temperature on performance during a 7.5-km cycling time trial.Eur J Appl Physiol. 2012 Sep;112(9):3387-95. doi: 10.1007/s00421-012-2316-x. Epub 2012 Jan 24. Eur J Appl Physiol. 2012. PMID: 22270485 Free PMC article. Clinical Trial.
-
Comparison of rectal and aural core body temperature thermometry in hyperthermic, exercising individuals: a meta-analysis.J Athl Train. 2012 May-Jun;47(3):329-38. doi: 10.4085/1062-6050-47.3.09. J Athl Train. 2012. PMID: 22892415 Free PMC article.
-
Validity of heart rate derived core temperature estimation during simulated firefighting tasks.Sci Rep. 2023 Dec 15;13(1):22503. doi: 10.1038/s41598-023-49929-x. Sci Rep. 2023. PMID: 38110650 Free PMC article.
-
Association between lower body temperature and increased tau pathology in cognitively normal older adults.Neurobiol Dis. 2022 Sep;171:105748. doi: 10.1016/j.nbd.2022.105748. Epub 2022 May 10. Neurobiol Dis. 2022. PMID: 35550158 Free PMC article. Clinical Trial.
-
Core temperature and sweat responses in professional women's tennis players during tournament play in the heat.J Athl Train. 2011 Jan-Feb;46(1):55-60. doi: 10.4085/1062-6050-46.1.55. J Athl Train. 2011. PMID: 21214351 Free PMC article.
References
-
- Sawka M N, Wenger C B. Physiological responses to acute exercise‐heat stress. In: Pandolf KB, Sawka MN, Gonzalez RR, eds. Human performance physiology and environmental medicine at terrestrial extremes. Indianapolis IN: Benchmark, 198897–151.
-
- American College of Sports Medicine Position stand. Heat and cold illnesses during distance running. Med Sci Sports Exerc 1996281–10. - PubMed
-
- Lim C L, Mackinnon L T. The roles of exercise‐induced immune system disturbances in the pathology of heat stroke. The dual pathway model of heat stroke. Sports Med 20063639–64. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical