Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
- PMID: 17183143
- DOI: 10.1088/0031-9155/52/1/020
Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
Abstract
The aim of this work was the Monte Carlo (MC) simulation of the response of commercially available dosimeters based on metal oxide semiconductor field effect transistors (MOSFETs) for radiotherapeutic photon beams using the PENELOPE code. The studied Thomson&Nielsen TN-502-RD MOSFETs have a very small sensitive area of 0.04 mm(2) and a thickness of 0.5 microm which is placed on a flat kapton base and covered by a rounded layer of black epoxy resin. The influence of different metallic and Plastic water build-up caps, together with the orientation of the detector have been investigated for the specific application of MOSFET detectors for entrance in vivo dosimetry. Additionally, the energy dependence of MOSFET detectors for different high-energy photon beams (with energy >1.25 MeV) has been calculated. Calculations were carried out for simulated 6 MV and 18 MV x-ray beams generated by a Varian Clinac 1800 linear accelerator, a Co-60 photon beam from a Theratron 780 unit, and monoenergetic photon beams ranging from 2 MeV to 10 MeV. The results of the validation of the simulated photon beams show that the average difference between MC results and reference data is negligible, within 0.3%. MC simulated results of the effect of the build-up caps on the MOSFET response are in good agreement with experimental measurements, within the uncertainties. In particular, for the 18 MV photon beam the response of the detectors under a tungsten cap is 48% higher than for a 2 cm Plastic water cap and approximately 26% higher when a brass cap is used. This effect is demonstrated to be caused by positron production in the build-up caps of higher atomic number. This work also shows that the MOSFET detectors produce a higher signal when their rounded side is facing the beam (up to 6%) and that there is a significant variation (up to 50%) in the response of the MOSFET for photon energies in the studied energy range. All the results have shown that the PENELOPE code system can successfully reproduce the response of a detector with such a small active area.
Similar articles
-
Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.Phys Med Biol. 2006 May 21;51(10):2549-66. doi: 10.1088/0031-9155/51/10/013. Epub 2006 May 4. Phys Med Biol. 2006. PMID: 16675869
-
Monte Carlo simulation using the PENELOPE code with an ant colony algorithm to study MOSFET detectors.Phys Med Biol. 2009 Oct 21;54(20):6263-76. doi: 10.1088/0031-9155/54/20/015. Epub 2009 Oct 1. Phys Med Biol. 2009. PMID: 19794247
-
Influence of electrodes on the photon energy deposition in CVD-diamond dosimeters studied with the Monte Carlo code PENELOPE.Phys Med Biol. 2006 Aug 7;51(15):3607-23. doi: 10.1088/0031-9155/51/15/001. Epub 2006 Jul 12. Phys Med Biol. 2006. PMID: 16861769
-
Dosimetry of clinical neutron and proton beams: an overview of recommendations.Radiat Prot Dosimetry. 2004;110(1-4):565-72. doi: 10.1093/rpd/nch221. Radiat Prot Dosimetry. 2004. PMID: 15353710 Review.
-
Monte Carlo simulations in radiotherapy dosimetry.Radiat Oncol. 2018 Jun 27;13(1):121. doi: 10.1186/s13014-018-1065-3. Radiat Oncol. 2018. PMID: 29945636 Free PMC article. Review.
Cited by
-
Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.Med Sci Monit. 2011 Jul;17(7):MT51-5. doi: 10.12659/msm.881833. Med Sci Monit. 2011. PMID: 21709641 Free PMC article.
-
Evaluation of clinical use of OneDose metal oxide semiconductor field-effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia.N Am J Med Sci. 2011 Aug;3(8):362-6. doi: 10.4297/najms.2011.3362. N Am J Med Sci. 2011. PMID: 22171243 Free PMC article.
-
Development of an applicator for eye lens dosimetry during radiotherapy.Br J Radiol. 2014 Oct;87(1042):20140311. doi: 10.1259/bjr.20140311. Epub 2014 Aug 11. Br J Radiol. 2014. PMID: 25111733 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous