Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2006 Dec;69(12):2896-901.
doi: 10.4315/0362-028x-69.12.2896.

Evaluation of an immunomagnetic separation-real-time PCR assay for the rapid detection of Salmonella in meat

Affiliations
Free article
Comparative Study

Evaluation of an immunomagnetic separation-real-time PCR assay for the rapid detection of Salmonella in meat

Angelika Notzon et al. J Food Prot. 2006 Dec.
Free article

Abstract

The aim of this study was the comparison of an immunomagnetic separation (IMS)-real-time PCR assay for the detection of Salmonella with the cultural reference method according to and 35 of the German Law on Food and Commodities (LMBG, L 00.00.20:1998). The IMS-real-time PCR assay includes a nonselective preenrichment step, an IMS, DNA extraction, as well as DNA purification followed by hybridization probe-based real-time PCR analysis. An accurate comparability was achieved, because both methods analyzed the same preenrichment. The evaluation was carried out using both artificially and naturally contaminated meat samples. The IMS-real-time PCR assay provides a result after 12 to 13 h. Compared with the reference method and regarding artificially contaminated meat samples, the IMS-real-time PCR assay achieved a specificity of 80% (false-positive rate of 20%) and a sensitivity of 100% (false-negative rate of 0%). The relative accuracy was 94%. The detection limit of both methods was 10 CFU/25 g. The concordance index kappa, which defines the statistical accordance, was 0.85 and indicated the agreement of both methods on statistical criteria. Compared to the reference method and analyzing naturally contaminated meat samples (n = 491), the IMS-real-time PCR assay showed a specificity of 99.3% (false-positive rate of 0.7%) and a sensitivity of 83.7% (false-negative rate of 16.3%). The relative accuracy was 98%. The concordance index kappa had a value of 0.87 and highlighted the statistical agreement of both methods. In conclusion, the IMS-real-time PCR assay is suitable as specific, sensitive, and rapid screening method for the detection of Salmonella from meat.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources