[Comparison of objective assessment using the sweep pattern visual evoked response acuity (SPVERA) and illiterate E visual acuity]
- PMID: 17190145
[Comparison of objective assessment using the sweep pattern visual evoked response acuity (SPVERA) and illiterate E visual acuity]
Abstract
Objective: To compare the vision objectively assessed by SPVERA with the illiterate E Acuity in normal subjects.
Methods: The effect of artificially induced image defocusing on visual acuities (Vas) measured by SPVEP and illiterate E chart measurement was studied in 14 normal subjects. SPVEP was recorded using vertical gratings of 8 different spatial frequencies ranging from 0.235 9 to 30.203 2 c/deg. The responses were averaged and displayed through the discrete Fourier transform on the monitor display. SPVERA was determined by extrapolating the PVER amplitude -spatial frequency function to baseline. SPVERA was compared with illiterate E visual acuity measured under the same conditions of optical defocus.
Results: With moderate defocusing (<+1.0 diopter (D),VA > 0.42), the SPVERA were equal to or poorer than the illiterate E visual acuity. With more defocus (> +2.0 diopter (D), VA < 0.3),the SPVERA became better than the illiterate E chart Visual Acuity. The correlation between the two acuities was r2 = 0.919.
Conclusion: SPVERA and the illiterate E visual acuity correlated to a certain degree. We conclude that the SPVERA is effective in estimating vision objectively.
Similar articles
-
Spatial frequency sweep pattern reversal VER acuity vs Snellen visual acuity: effect of optical defocus.Vision Res. 1996 Mar;36(6):903-9. doi: 10.1016/0042-6989(95)00187-5. Vision Res. 1996. PMID: 8736223
-
Sweep pattern visual evoked potential acuity in children during their periods of visual development.Ophthalmologica. 2011;226(4):220-7. doi: 10.1159/000329866. Epub 2011 Jul 29. Ophthalmologica. 2011. PMID: 21811053
-
[Establishment of the sweep pattern visual evoked potential system and its application].Fa Yi Xue Za Zhi. 2009 Apr;25(2):88-91. Fa Yi Xue Za Zhi. 2009. PMID: 19537243 Chinese.
-
[Visual electrophysiology and objective visual function].Fa Yi Xue Za Zhi. 2002 May;18(2):115-7. Fa Yi Xue Za Zhi. 2002. PMID: 12596599 Review. Chinese.
-
The technique, validity and clinical use of the sweep VEP.Ophthalmic Physiol Opt. 2008 Sep;28(5):393-403. doi: 10.1111/j.1475-1313.2008.00591.x. Ophthalmic Physiol Opt. 2008. PMID: 18761477 Review.
Publication types
MeSH terms
LinkOut - more resources
Medical