A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation
- PMID: 17194494
- DOI: 10.1016/j.radonc.2006.11.021
A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation
Abstract
Purpose and background: Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast irradiation for their radiation conformity index, dose homogeneity index, and dose to organs at risk.
Methods and materials: Small-field tangents, three-dimensional conformal radiation therapy, intensity-modulated radiation therapy and helical tomotherapy were compared for each of 15 patients (7 right, 8 left). One radiation conformity and two dose homogeneity indices were used to evaluate the dose to the target. The mean dose to organs at risk was also evaluated.
Results: All proposed APBI techniques improved the conformity index significantly over whole breast tangents while maintaining dose homogeneity and without a significant increase in dose to organs at risk.
Conclusion: The four-field IMRT plan produced the best dosimetric results; however this technique would require appropriate respiratory motion management. An alternative would be to use a four-field conformal technique that is less sensitive to the effects of respiratory motion.
Similar articles
-
Dosimetric comparison of four different external beam partial breast irradiation techniques: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy.Radiother Oncol. 2009 Jan;90(1):66-73. doi: 10.1016/j.radonc.2008.09.027. Epub 2008 Nov 5. Radiother Oncol. 2009. PMID: 18992950
-
[Dosimetric evaluation of intensity-modulated tangential beam versus conventional tangential irradiation for breast cancer].Ai Zheng. 2006 Jul;25(7):855-60. Ai Zheng. 2006. PMID: 16831277 Chinese.
-
Dosimetric evaluation of conventional radiotherapy, 3-D conformal radiotherapy and direct machine parameter optimisation intensity-modulated radiotherapy for breast cancer after conservative surgery.J Med Imaging Radiat Oncol. 2011 Dec;55(6):595-602. doi: 10.1111/j.1754-9485.2011.02313.x. J Med Imaging Radiat Oncol. 2011. PMID: 22141607
-
Accelerated partial breast irradiation: consensus statement of 3 German Oncology societies.Cancer. 2007 Sep 15;110(6):1187-94. doi: 10.1002/cncr.22910. Cancer. 2007. PMID: 17647249 Review.
-
Accelerated partial breast irradiation in early-stage breast cancer.J Clin Oncol. 2007 Mar 10;25(8):996-1002. doi: 10.1200/JCO.2006.09.7436. J Clin Oncol. 2007. PMID: 17350949 Review.
Cited by
-
Dosimetric effects of prone immobilization devices on skin in intensity-modulated radiation therapy for gynecologic cancer: a retrospective study.BMC Cancer. 2024 Nov 28;24(1):1464. doi: 10.1186/s12885-024-13111-x. BMC Cancer. 2024. PMID: 39609758 Free PMC article.
-
Dosimetric comparison of normal structures associated with accelerated partial breast irradiation and whole breast irradiation delivered by intensity modulated radiotherapy for early breast cancer after breast conserving surgery.Clin Transl Oncol. 2014 Jan;16(1):69-76. doi: 10.1007/s12094-013-1044-y. Epub 2013 Apr 25. Clin Transl Oncol. 2014. PMID: 23615981
-
Comparison of whole brain radiation therapy for synchronous brain metastases with irradiation protecting the hippocampus versus whole brain radiotherapy for sequential brain metastases to boost irradiation in the treatment of brain metastases from SCLC: study protocol for a randomized controlled trial.Trials. 2022 Oct 14;23(1):876. doi: 10.1186/s13063-022-06826-4. Trials. 2022. PMID: 36242060 Free PMC article.
-
Initial validation and clinical experience with 3D optical-surface-guided whole breast irradiation of breast cancer.Technol Cancer Res Treat. 2012 Feb;11(1):57-68. doi: 10.7785/tcrt.2012.500235. Technol Cancer Res Treat. 2012. PMID: 22181332 Free PMC article. Clinical Trial.
-