Experience with a new implantable pacer-, cardioverter-defibrillator for the therapy of recurrent sustained ventricular tachyarrhythmias: a step toward a universal ventricular tachyarrhythmia control device
- PMID: 1719507
- DOI: 10.1111/j.1540-8159.1991.tb02869.x
Experience with a new implantable pacer-, cardioverter-defibrillator for the therapy of recurrent sustained ventricular tachyarrhythmias: a step toward a universal ventricular tachyarrhythmia control device
Abstract
Ten consecutive patients (mean age 57.9 +/- 7.6 years) were treated with an investigational tachyarrhythmia control device, the implantable Medtronic Pacer-, Cardioverter-, Defibrillator model 7216A or 7217B. All patients had coronary artery disease with old myocardial infarctions and presented hemodynamically significant sustained ventricular tachyarrhythmias not suppressed by antiarrhythmic drug therapy and unrelated to acute myocardial infarction. In two patients a nonthoracotomy lead system was implanted. Lowest effective defibrillation energy ranged from 5 to 18 joules (mean 12.2 +/- 4 joules) for the epicardial bielectrode systems and were 15 and 18 joules for the nonthoracotomy lead system implants. The postoperative periods were unremarkable. Follow-up ranged from 7 to 19 months (mean 13.8 +/- 4.5 months). Spontaneous tachyarrhythmia episodes were detected and treated by the device in six patients, five of them received staged therapies. No deaths occurred and no hospital admissions were necessary for device related or ventricular tachyarrhythmia related complications. In conclusion, this integrated device represents a major step toward the development of a universal ventricular arrhythmia control device.
Similar articles
-
Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.Circulation. 1992 Aug;86(2):363-74. doi: 10.1161/01.cir.86.2.363. Circulation. 1992. PMID: 1638705 Clinical Trial.
-
Experience with a third-generation implantable cardioverter-defibrillator.Am J Cardiol. 1991 Jun 15;67(16):1375-84. doi: 10.1016/0002-9149(91)90468-z. Am J Cardiol. 1991. PMID: 2042568
-
Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.Arch Intern Med. 1989 Oct;149(10):2333-9. Arch Intern Med. 1989. PMID: 2802898
-
[Clinical assessment and indications for automatic defibrillation].Ther Umsch. 1992 Aug;49(8):580-5. Ther Umsch. 1992. PMID: 1519187 Review. German.
-
[The implantable automatic cardioverter-defibrillator].Herz. 1990 Apr;15(2):111-25. Herz. 1990. PMID: 2188891 Review. German.
Cited by
-
Experience with unipolar pectoral defibrillation.Herzschrittmacherther Elektrophysiol. 1997 Mar;8(1):32-8. doi: 10.1007/BF03042475. Herzschrittmacherther Elektrophysiol. 1997. PMID: 19495675
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical