Abstract
High brightness light emitting diodes are an inexpensive and versatile light source for wide-field frequency-domain fluorescence lifetime imaging microscopy. In this paper a full calibration of an LED based fluorescence lifetime imaging microscopy system is presented for the first time. A radio-frequency generator was used for simultaneous modulation of light emitting diode (LED) intensity and the gain of an intensified charge coupled device (CCD) camera. A homodyne detection scheme was employed to measure the demodulation and phase shift of the emitted fluorescence, from which phase and modulation lifetimes were determined at each image pixel. The system was characterized both in terms of its sensitivity to measure short lifetimes (500 ps to 4 ns), and its capability to distinguish image features with small lifetime differences. Calibration measurements were performed in quenched solutions containing Rhodamine 6G dye and the results compared to several independent measurements performed with other measurement methodologies, including time correlated single photon counting, time gated detection, and acousto optical modulator (AOM) based modulation of excitation sources. Results are presented from measurements and simulations. The effects of limited signal-to-noise ratios, baseline drifts and calibration errors are discussed in detail. The implications of limited modulation bandwidth of high brightness, large area LED devices ( approximately 40 MHz for devices used here) are presented. The results show that phase lifetime measurements are robust down to sub ns levels, whereas modulation lifetimes are prone to errors even at large signal-to-noise ratios. Strategies for optimizing measurement fidelity are discussed. Application of the fluorescence lifetime imaging microscopy system is illustrated with examples from studies of molecular mixing in microfluidic devices and targeted drug delivery research.
Similar articles
-
Fluorescence lifetime imaging: multi-point calibration, minimum resolvable differences, and artifact suppression.Cytometry. 2001 Apr 1;43(4):248-60. doi: 10.1002/1097-0320(20010401)43:4<248::aid-cyto1057>3.0.co;2-y. Cytometry. 2001. PMID: 11260592
-
phiFLIM: a new method to avoid aliasing in frequency-domain fluorescence lifetime imaging microscopy.J Microsc. 2004 Jan;213(1):29-38. doi: 10.1111/j.1365-2818.2004.01249.x. J Microsc. 2004. PMID: 14678510
-
Modulated CMOS camera for fluorescence lifetime microscopy.Microsc Res Tech. 2015 Dec;78(12):1075-81. doi: 10.1002/jemt.22587. Epub 2015 Oct 24. Microsc Res Tech. 2015. PMID: 26500051 Free PMC article.
-
Light-emitting diodes in modern microscopy--from David to Goliath?Cytometry A. 2012 Mar;81(3):188-97. doi: 10.1002/cyto.a.22023. Epub 2012 Jan 30. Cytometry A. 2012. PMID: 22290727 Review.
-
[A new approach for studying the retinal and choroidal circulation].Nippon Ganka Gakkai Zasshi. 2004 Dec;108(12):836-61; discussion 862. Nippon Ganka Gakkai Zasshi. 2004. PMID: 15656089 Review. Japanese.
Cited by
-
Assessing Wound Healing in Vivo Using a Dual-Function Phosphorescent Probe Sensitive to Tissue Oxygenation and Regenerating Collagen.ACS Appl Mater Interfaces. 2025 Jan 8;17(1):398-407. doi: 10.1021/acsami.4c15069. Epub 2024 Dec 27. ACS Appl Mater Interfaces. 2025. PMID: 39730313 Free PMC article.
-
Wearable device for remote monitoring of transcutaneous tissue oxygenation.Biomed Opt Express. 2020 Nov 9;11(12):6989-7002. doi: 10.1364/BOE.408850. eCollection 2020 Dec 1. Biomed Opt Express. 2020. PMID: 33408975 Free PMC article.
-
Simple and Robust Deep Learning Approach for Fast Fluorescence Lifetime Imaging.Sensors (Basel). 2022 Sep 26;22(19):7293. doi: 10.3390/s22197293. Sensors (Basel). 2022. PMID: 36236390 Free PMC article.
-
Direct frequency domain fluorescence lifetime imaging using simultaneous ultraviolet and visible excitation.Biomed Opt Express. 2023 Mar 23;14(4):1608-1625. doi: 10.1364/BOE.480287. eCollection 2023 Apr 1. Biomed Opt Express. 2023. PMID: 37078041 Free PMC article.
-
Mercury free microscopy: an opportunity for core facility directors.J Biomol Tech. 2014 Jul;25(2):48-53. doi: 10.7171/jbt.14-2502-001. J Biomol Tech. 2014. PMID: 24982596 Free PMC article.