Advances in imaging of the optic disc and retinal nerve fiber layer
- PMID: 17204925
- DOI: 10.1097/01.wno.0000249327.65227.67
Advances in imaging of the optic disc and retinal nerve fiber layer
Abstract
In the past decade, three technologies for imaging the optic disc and retinal nerve fiber layer have become commercially available: 1) confocal scanning laser tomography with the Heidelberg retinal tomograph; 2) confocal scanning laser polarimetry with the GDx VCC; and 3) optical coherence tomography with the Stratus OCT. Each uses different principles of physics. Understanding the merits and limitations of each of these technologies requires familiarity with the principles of operation of each device. This knowledge should be considered a prerequisite for the appropriate clinical utilization of these devices and for accurate interpretation of their results.
Similar articles
-
Diagnostic ability of the Heidelberg retina tomograph, optical coherence tomograph, and scanning laser polarimeter in open-angle glaucoma.J Glaucoma. 2007 Mar;16(2):173-7. doi: 10.1097/IJG.0b013e31802dfc1d. J Glaucoma. 2007. PMID: 17473725
-
Comparison of quantitative imaging devices and subjective optic nerve head assessment by general ophthalmologists to differentiate normal from glaucomatous eyes.J Glaucoma. 2009 Mar;18(3):253-61. doi: 10.1097/IJG.0b013e31818153da. J Glaucoma. 2009. PMID: 19295383
-
Retinal imaging by laser polarimetry and optical coherence tomography evidence of axonal degeneration in multiple sclerosis.Arch Neurol. 2008 Jul;65(7):924-8. doi: 10.1001/archneur.65.7.924. Arch Neurol. 2008. PMID: 18625859
-
[High tech in the diagnosis of glaucoma].Klin Monbl Augenheilkd. 2006 Jun;223(6):503-8. doi: 10.1055/s-2005-859004. Klin Monbl Augenheilkd. 2006. PMID: 16804820 Review. German.
-
Nonarteritic anterior ischaemic optic neuropathy.Curr Opin Ophthalmol. 2008 Nov;19(6):461-7. doi: 10.1097/ICU.0b013e3283112bc8. Curr Opin Ophthalmol. 2008. PMID: 18854690 Review.
Cited by
-
Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry.Front Neurosci. 2015 Dec 18;9:479. doi: 10.3389/fnins.2015.00479. eCollection 2015. Front Neurosci. 2015. PMID: 26733792 Free PMC article.
-
Functional imaging using the retinal function imager: direct imaging of blood velocity, achieving fluorescein angiography-like images without any contrast agent, qualitative oximetry, and functional metabolic signals.Jpn J Ophthalmol. 2009 Jul;53(4):345-51. doi: 10.1007/s10384-009-0689-0. Epub 2009 Sep 8. Jpn J Ophthalmol. 2009. PMID: 19763751 Review.
-
Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?Biomed Res Int. 2015;2015:813242. doi: 10.1155/2015/813242. Epub 2015 Jun 8. Biomed Res Int. 2015. PMID: 26167499 Free PMC article. Review.
-
Retinal nerve fiber layer changes in migraine: A protocol for systematic review and meta-analysis.Medicine (Baltimore). 2020 Aug 14;99(33):e21680. doi: 10.1097/MD.0000000000021680. Medicine (Baltimore). 2020. PMID: 32872037 Free PMC article.
-
Topographic optic disc analysis by Heidelberg retinal tomography in ocular Behcet's disease.Br J Ophthalmol. 2007 Sep;91(9):1199-201. doi: 10.1136/bjo.2007.116087. Epub 2007 May 2. Br J Ophthalmol. 2007. PMID: 17475703 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical