Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography
- PMID: 17206429
- DOI: 10.1007/s00330-006-0502-0
Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography
Abstract
We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.
Similar articles
-
Coronary stent imaging with dual-source CT: assessment of lumen visibility using different convolution kernels and postprocessing filters.Acta Radiol. 2015 Jan;56(1):42-50. doi: 10.1177/0284185113517229. Epub 2014 Jan 7. Acta Radiol. 2015. PMID: 24399513
-
Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: comparison of a medium-smooth kernel and a sharp kernel.Eur J Radiol. 2009 May;70(2):362-8. doi: 10.1016/j.ejrad.2008.01.039. Epub 2008 Mar 21. Eur J Radiol. 2009. PMID: 18359179 Clinical Trial.
-
Computed tomography coronary stent imaging with iterative reconstruction: a trade-off study between medium kernel and sharp kernel.J Comput Assist Tomogr. 2014 Jul-Aug;38(4):604-12. doi: 10.1097/RCT.0000000000000080. J Comput Assist Tomogr. 2014. PMID: 24651753
-
Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.Radiology. 2004 Oct;233(1):286-91. doi: 10.1148/radiol.2331031564. Epub 2004 Aug 10. Radiology. 2004. PMID: 15304660
-
First experience with single-source, dual-energy CCTA for monochromatic stent imaging.Eur Heart J Cardiovasc Imaging. 2015 May;16(5):507-12. doi: 10.1093/ehjci/jeu282. Epub 2014 Dec 18. Eur Heart J Cardiovasc Imaging. 2015. PMID: 25525062
Cited by
-
Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary angiography.J Geriatr Cardiol. 2016 Oct;13(10):817-823. doi: 10.11909/j.issn.1671-5411.2016.10.002. J Geriatr Cardiol. 2016. PMID: 27928222 Free PMC article.
-
Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis.Eur Radiol. 2008 Feb;18(2):217-25. doi: 10.1007/s00330-007-0743-6. Epub 2007 Sep 1. Eur Radiol. 2008. PMID: 17763854
-
Assessment of in-stent restenosis using 64-MDCT: analysis of the CORE-64 Multicenter International Trial.AJR Am J Roentgenol. 2010 Jan;194(1):85-92. doi: 10.2214/AJR.09.2652. AJR Am J Roentgenol. 2010. PMID: 20028909 Free PMC article. Clinical Trial.
-
Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography.Eur Radiol. 2008 Feb;18(2):234-43. doi: 10.1007/s00330-007-0756-1. Epub 2007 Oct 10. Eur Radiol. 2008. PMID: 17929024
-
Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts.Br J Radiol. 2020 Nov 1;93(1115):20200078. doi: 10.1259/bjr.20200078. Epub 2020 Aug 20. Br J Radiol. 2020. PMID: 32816561 Free PMC article. Clinical Trial.