Application of lactate amperometric sol-gel biosensor to sequential injection determination of L-lactate
- PMID: 17207600
- DOI: 10.1016/j.jpba.2006.11.027
Application of lactate amperometric sol-gel biosensor to sequential injection determination of L-lactate
Abstract
This work describes the construction and evaluation of lactate sol-gel biosensors to accomplish the determination of lactate in pharmaceutical products. Lactate oxidase was incorporated in a porous sol-gel film placed onto a platinum-based electrode. Acid and basic catalysis were assessed. When coupled to a sequential injection system (SIA) the biosensor, based on (3-aminopropyl)trimethoxysilane, 2-(3,4-epoxycyclohexyl)ethyl-trimethoxysilane, deionised water, polyethylene glycol 6000 and acid catalyst, presented a range of linearity of 5x10(-5) to 5x10(-3)M. The analytical usefulness of the developed biosensor was evaluated through analysis of commercial pharmaceutical products containing lactate with a sampling rate of 40 samples h(-1). The enzyme remained active for at least 30 days, enabling about 700 determinations without sensitivity decrease.
Similar articles
-
Amperometric biosensor based on monoamine oxidase (MAO) immobilized in sol-gel film for benzydamine determination in pharmaceuticals.J Pharm Biomed Anal. 2003 Dec 4;33(5):983-90. doi: 10.1016/s0731-7085(03)00378-9. J Pharm Biomed Anal. 2003. PMID: 14656589
-
Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide.Anal Chem. 2007 May 15;79(10):3757-63. doi: 10.1021/ac061972d. Epub 2007 Apr 7. Anal Chem. 2007. PMID: 17417817
-
Sol-gel immobilization of lactate oxidase from organic solvent: toward the advanced lactate biosensor.Anal Chem. 2010 Mar 1;82(5):1601-4. doi: 10.1021/ac9027615. Anal Chem. 2010. PMID: 20136130
-
Enzyme inhibition-based biosensors for food safety and environmental monitoring.Biosens Bioelectron. 2006 Feb 15;21(8):1405-23. doi: 10.1016/j.bios.2005.07.012. Epub 2005 Aug 25. Biosens Bioelectron. 2006. PMID: 16125923 Review.
-
The potential of biosensor technology in clinical monitoring and experimental research.Biomed Mater Eng. 2004;14(4):455-64. Biomed Mater Eng. 2004. PMID: 15472394 Review.
Cited by
-
Novel Siloxane Derivatives as Membrane Precursors for Lactate Oxidase Immobilization.Sensors (Basel). 2023 Apr 15;23(8):4014. doi: 10.3390/s23084014. Sensors (Basel). 2023. PMID: 37112357 Free PMC article.
-
Application of electrochemical biosensors in clinical diagnosis.J Clin Lab Anal. 2012 Jan;26(1):22-34. doi: 10.1002/jcla.20500. J Clin Lab Anal. 2012. PMID: 24833531 Free PMC article. Review.
-
Recent Progress in Electrochemical Nano-Biosensors for Detection of Pesticides and Mycotoxins in Foods.Biosensors (Basel). 2023 Jan 14;13(1):140. doi: 10.3390/bios13010140. Biosensors (Basel). 2023. PMID: 36671974 Free PMC article. Review.
-
Biosensors based on electrochemical lactate detection: A comprehensive review.Biochem Biophys Rep. 2015 Nov 11;5:35-54. doi: 10.1016/j.bbrep.2015.11.010. eCollection 2016 Mar. Biochem Biophys Rep. 2015. PMID: 28955805 Free PMC article. Review.
-
Adaptable Xerogel-Layered Amperometric Biosensor Platforms on Wire Electrodes for Clinically Relevant Measurements.Sensors (Basel). 2019 Jun 6;19(11):2584. doi: 10.3390/s19112584. Sensors (Basel). 2019. PMID: 31174353 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources