Seven years' experience with Integra as a reconstructive tool
- PMID: 17211211
- DOI: 10.1097/BCR.0b013E31802CB83F
Seven years' experience with Integra as a reconstructive tool
Abstract
The bilayered dermal substitute Integra (Integra Life Sciences Corp., Plainsboro, NJ) was developed and has been widely used as primary coverage for excised acute burns. Our take has been slightly different, finding it most useful in the management of complex soft-tissue loss and threatened extremities as the result of tendon, joint, or bone exposure. Often tasked to fill significant volume loss, we have become adept at stacked multiple-layer applications. Creative use of this material has resulted in unexpected successes with distal limb salvage; the technique takes its place beside adjacent tissue transfer, composite flaps, and vascular pedicle flaps in our burn reconstructive practice. A prospective registry (44 patients) has been kept during the past 7 years that catalogs wounds with complex soft-tissue loss treated with Integra grafts. Many of these patients were at risk of extremity loss because of exposed tendons, joints, or bone. Integra was applied after 1:1 meshing. With profound soft-tissue defects, multiple layers of Integra were serially applied 1 to 2 weeks apart for reconstitution of soft-tissue contours. Local Integra graft infections were managed by silicone unroofing followed by topical sulfamylon liquid dressings. Wounds addressed included fourth-degree burns, necrotizing fasciitis, pit-viper envenomations, and total abdominal wall avulsion in one patient after being run over by a bus. Patients generally were free of pain from their wounds during the maturation phase of the Integra neodermis. Restoration of tissue contour was significantly better when using multiple layers for deep defects. Second and third layers of Integra were successfully applied after an abbreviated first graft maturation period of 7 days. Epithelial autografts on multilayer Integra applications frequently "ghosted"; they would auto-digest to dispersed cells followed subsequently by the reappearance of a confluent epithelial layer. Final grafted skin morphology over palmar and plantar surfaces assumed the type and fingerprint pattern of the original tissues. Infections were readily visible. Early recognition kept them to easily treated circumscribed areas, which did not jeopardize the entire wound. Lengths of stay were long (range, 2-246 days) but not significantly greater than with traditional techniques. The specific reconstructive use of Integra permitted unexpected salvage of several threatened extremities by protecting exposed tendons, bones and joints. Long-term histologic examination revealed unexpected persistence of Integra collagen. Large volume loss wounds benefited from the ability to fill voids with multilayered applications.
Similar articles
-
Tendon coverage using an artificial skin substitute.J Plast Reconstr Aesthet Surg. 2012 Nov;65(11):1544-50. doi: 10.1016/j.bjps.2012.05.021. Epub 2012 Jun 20. J Plast Reconstr Aesthet Surg. 2012. PMID: 22721977
-
An objective long-term evaluation of Integra (a dermal skin substitute) and split thickness skin grafts, in acute burns and reconstructive surgery.Burns. 2010 Feb;36(1):23-8. doi: 10.1016/j.burns.2009.07.011. Epub 2009 Oct 27. Burns. 2010. PMID: 19864070
-
The 1999 clinical research award. Cultured skin substitutes combined with Integra Artificial Skin to replace native skin autograft and allograft for the closure of excised full-thickness burns.J Burn Care Rehabil. 1999 Nov-Dec;20(6):453-61. doi: 10.1097/00004630-199920060-00006. J Burn Care Rehabil. 1999. PMID: 10613682
-
Reconstruction of Complex Full-Thickness Scalp Defects After Dog-Bite Injuries Using Dermal Regeneration Template (Integra): Case Report and Literature Review.J Oral Maxillofac Surg. 2019 Feb;77(2):338-351. doi: 10.1016/j.joms.2018.08.022. Epub 2018 Sep 4. J Oral Maxillofac Surg. 2019. PMID: 30267703
-
Management of septic skin necroses.Eur J Pediatr Surg. 2013 Oct;23(5):349-58. doi: 10.1055/s-0033-1352530. Epub 2013 Sep 5. Eur J Pediatr Surg. 2013. PMID: 24008550 Review.
Cited by
-
Dermal regenerative matrix use in burn patients: A systematic review.J Plast Reconstr Aesthet Surg. 2019 Nov;72(11):1741-1751. doi: 10.1016/j.bjps.2019.07.021. Epub 2019 Aug 8. J Plast Reconstr Aesthet Surg. 2019. PMID: 31492583 Free PMC article.
-
About ATMPs, SOPs and GMP: The Hurdles to Produce Novel Skin Grafts for Clinical Use.Transfus Med Hemother. 2016 Sep;43(5):344-352. doi: 10.1159/000447645. Epub 2016 Sep 6. Transfus Med Hemother. 2016. PMID: 27781022 Free PMC article. Review.
-
Dermal Regeneration Template in the Management and Reconstruction of Burn Injuries and Complex Wounds: A Review.Plast Reconstr Surg Glob Open. 2024 Mar 20;12(3):e5674. doi: 10.1097/GOX.0000000000005674. eCollection 2024 Mar. Plast Reconstr Surg Glob Open. 2024. PMID: 38510326 Free PMC article.
-
Regenerative medicine as applied to general surgery.Ann Surg. 2012 May;255(5):867-80. doi: 10.1097/SLA.0b013e318243a4db. Ann Surg. 2012. PMID: 22330032 Free PMC article. Review.
-
Reconstruction of a Pediatric Distal Phalanx Amputation With Stacked Integra Dermal Substitute: A Case Report.Cureus. 2024 Apr 23;16(4):e58856. doi: 10.7759/cureus.58856. eCollection 2024 Apr. Cureus. 2024. PMID: 38800231 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous